Suppr超能文献

正常受试者每日四次测量的血浆皮质醇水平呈对数正态分布。德穆尔荧光法与血浆皮质醇放射免疫测定法的比较(作者译)

[Log-normal distributed plasma cortisol levels of four daily measurements in normal subjects. A comparison of the fluorescence method after de Moor with a radioimmuno assay of plasma cortisol (author's transl)].

作者信息

Hartmann F

出版信息

Med Klin. 1977 Mar 4;72(9):353-6.

PMID:840147
Abstract

The present paper describes the plasma cortisol concentrations on four daily measurements in normal subjects assayed with the fluorescence method after de Moor and with a radioimmuno assay. A comparison of these two methods shows that the determinations of plasma cortisol with the fluorescence method always yielded higher values. Both methods are sensitive enough to detect the circadian rhythm of cortisol secretion. For the purpose of routine diagnostics it is sufficient to measure the maximal and minimal concentrations of plasma cortisol in blood samples taken at 8 a.m. and 8 p.m., respectively. The plasma cortisol measurements should only be attempted after allowing a few days of adaption to the hospital situation. Table 2 shows that the normal plasma cortisol levels are represented only by log-normal distributed values. These concentrations are lower than the linear distributed levels reported so far.

摘要

本文描述了采用德·穆尔荧光法和放射免疫分析法对正常受试者进行的每日四次血浆皮质醇浓度测定。这两种方法的比较表明,荧光法测定血浆皮质醇的值总是更高。两种方法都足够灵敏,能够检测到皮质醇分泌的昼夜节律。为了进行常规诊断,分别在上午8点和晚上8点采集的血样中测量血浆皮质醇的最大和最小浓度就足够了。血浆皮质醇测量应在适应医院环境几天后再进行。表2显示,正常血浆皮质醇水平仅由对数正态分布值表示。这些浓度低于迄今为止报道的线性分布水平。