Vlaspolder F, Mutsaers J A, Blog F, Notowicz A
Department of Medical Microbiology, Westeinde Hospital, The Hague, The Netherlands.
J Clin Microbiol. 1993 Jan;31(1):107-10. doi: 10.1128/jcm.31.1.107-110.1993.
The Gen-Probe PACE 2 system for Neisseria gonorrhoeae (GP), which uses a chemiluminescently labeled DNA probe, was compared with conventional culture as the method of reference. A total of 1,750 specimens were collected from 496 females and 623 males visiting the outpatient clinic of the Sexually Transmitted Diseases Department of the Westeinde Hospital, The Hague, The Netherlands, during the year 1991. The prevalences of gonorrhea culture-positive men and women were 14.9 and 7.7%, respectively. The overall positive rate was 8.7%. Sensitivity, specificity, and positive and negative predictive values of GP were 97.1, 99.1, 90.6, and 99.8%, respectively. A total of 12 of 13 patients with positive GP results and negative cultures may have had a gonococcal infection, a conclusion based on clinical symptoms, positive methylene blue smears, and high relative light unit ratios. The DNA probe test can be useful as a suitable screening and diagnostic test for gonorrheal infection in men and women. An advantage of using this DNA probe technique is that simultaneous testing for Chlamydia trachomatis of the same specimen is possible. We also examined whether (all) rRNA had disappeared after adequate treatment for gonococcal and/or chlamydial infection in 30 patients. None of those positive patients showed a positive result in the DNA probe assay after treatment.
将用于淋病奈瑟菌检测的Gen-Probe PACE 2系统(GP)与作为参考方法的传统培养法进行了比较。1991年期间,从荷兰海牙韦斯特恩德医院性病科门诊就诊的496名女性和623名男性中总共采集了1750份标本。淋病培养阳性的男性和女性患病率分别为14.9%和7.7%。总体阳性率为8.7%。GP的敏感性、特异性、阳性预测值和阴性预测值分别为97.1%、99.1%、90.6%和99.8%。13例GP结果阳性但培养阴性的患者中,共有12例可能患有淋球菌感染,这一结论基于临床症状、亚甲蓝涂片阳性以及高相对光单位比值。DNA探针检测可作为男性和女性淋病感染的合适筛查和诊断检测方法。使用这种DNA探针技术的一个优点是可以对同一份标本同时进行沙眼衣原体检测。我们还检查了30例淋病和/或衣原体感染患者在接受充分治疗后(所有)rRNA是否消失。这些阳性患者在治疗后DNA探针检测均未显示阳性结果。