Suppr超能文献

Metrecom用于无生命物体长度测量的可靠性和同时效度。

Reliability and concurrent validity of the Metrecom for length measurements on inanimate objects.

作者信息

Norton B J, Ellison J B

机构信息

Applied Kinesiology Laboratories, Washington University School of Medicine, St Louis, MO 63110.

出版信息

Phys Ther. 1993 Apr;73(4):266-74. doi: 10.1093/ptj/73.4.266.

Abstract

BACKGROUND AND PURPOSE

The purpose of this study was to test the reliability and concurrent validity of length measurements (distance between two points) produced by a computer-interfaced, three-dimensional digitizer called the Metrecom.

METHODS

A total of 344 points were marked on the surfaces of five different inanimate objects and were digitized in pairs with the Metrecom. On the first three objects, each of two testers digitized each point twice for each of two testing modes (Line Length and 3-D Digitizer); on the last two objects, only one mode (3-D Digitizer) was used. Intraclass correlation coefficients and Pearson Product-Moment Correlation Coefficients were used to assess reliability and concurrent validity, respectively.

RESULTS

All of the correlation coefficients were > or = .99. In further analysis of the results, a repeated-measures, one-way analysis of variance (used with reliability data) and repeated-measures t tests (used with validity data) were used to test for differences between repeated measures. After adjustment of the alpha level for the total number of comparisons, two of the t tests for validity comparisons were significant.

CONCLUSION AND DISCUSSION

The results indicate that the Metrecom provides reliable length measurements (distance between two points) on inanimate objects and that two different test modes produce consistent measurements. Further study of the validity and reliability of length measurements obtained with the Metrecom on humans under applied conditions is needed before the results of this study can be generalized to applied settings.

摘要

背景与目的

本研究旨在测试一种名为Metrecom的计算机接口三维数字化仪所产生的长度测量值(两点之间的距离)的可靠性和同时效度。

方法

在五个不同的无生命物体表面共标记了344个点,并使用Metrecom对其进行成对数字化处理。对于前三个物体,两名测试者分别在两种测试模式(线长和三维数字化仪)下对每个点进行两次数字化处理;对于后两个物体,仅使用一种模式(三维数字化仪)。组内相关系数和皮尔逊积差相关系数分别用于评估可靠性和同时效度。

结果

所有相关系数均≥0.99。在对结果的进一步分析中,使用重复测量的单因素方差分析(用于可靠性数据)和重复测量t检验(用于效度数据)来检验重复测量之间的差异。在对比较总数的α水平进行调整后,两个效度比较的t检验具有显著性。

结论与讨论

结果表明,Metrecom能在无生命物体上提供可靠的长度测量值(两点之间的距离),且两种不同的测试模式产生的测量结果一致。在本研究结果能够推广到实际应用场景之前,需要进一步研究在实际应用条件下使用Metrecom对人体进行长度测量的效度和可靠性。