• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Comparison of various agents in contrast enhancement of color Doppler flow images: an in vitro study.

作者信息

Fan P, Czuwala P J, Nanda N C, Rosenthal S M, Yoganathan A

机构信息

Division of Cardiovascular Disease, University of Alabama, Birmingham 35233.

出版信息

Ultrasound Med Biol. 1993;19(1):45-57. doi: 10.1016/0301-5629(93)90017-i.

DOI:10.1016/0301-5629(93)90017-i
PMID:8456528
Abstract

The commercially manufactured contrast agents, Echovist and Albunex, were compared with sonicated conventional agents, indocyanine green, 29% renografin-60, 0.9% normal saline and 25% mannitol in their ability to enhance color Doppler flow signals. In a pneumatically regulated pulsatile flow system, a glycerine, saline (0.9%) and sand (5 microns particle size) solution was imaged using a 2.5 MHz phased-array transducer. Four different flow velocities (0.40, 0.35, 0.30 and 0.25 m/s) as measured by color Doppler guided pulse Doppler were utilized. All color Doppler settings were kept constant throughout the study. Utilizing a power injector, four different volumes (1.0, 1.5, 2.0 and 2.5 mL) of each contrast agent were injected into the flow medium at various transducer angles (20, 30, 40 and 60 degrees) and various distances from the transducer (3.38, 5.5, 6.76 cm). For Echovist and Albunex, several concentrations varying from 2% to 100% were used. Keeping instrument settings constant, color flow areas obtained before and after each contrast injection were planimeterized and the percent increase in the color flow area computed and compared. At full (100%) concentration, 20 degrees transducer angle and a flow velocity of 0.40 m/s, the maximum increase in the color flow area was 568%, 251%, 180%, 110%, 71%, and 38% for Echovist, Albunex, sonicated indocyanine green, renografin, normal saline and mannitol, respectively. However, a significant reduction in the degree of color flow enhancement was observed, with decreases in the concentration of these agents, and increases in the Doppler beam incident angle or distance from the transducer. Increasing the flow velocity of the medium into which contrast was injected did not produce significant changes in the contrast enhancement effect for all agents except Echovist. Increasing the injection volume significantly increased the color flow area for sonicated agents but not for Echovist or Albunex. This preliminary in vitro study shows that the commercially manufactured contrast agents, Echovist and Albunex, are much superior to sonicated conventional contrast agents in the enhancement of color Doppler flow signals. Of the sonicated agents, indocyanine green had the best enhancement capability.

摘要

相似文献

1
Comparison of various agents in contrast enhancement of color Doppler flow images: an in vitro study.
Ultrasound Med Biol. 1993;19(1):45-57. doi: 10.1016/0301-5629(93)90017-i.
2
Echo contrast agents improve flow display of color Doppler: in vitro studies.超声造影剂改善彩色多普勒血流显示:体外研究
Echocardiography. 1991 Sep;8(5):533-40. doi: 10.1111/j.1540-8175.1991.tb01014.x.
3
Transesophageal color Doppler evaluation of obstructive lesions using the new "Quasar" technology.使用新型“类星体”技术经食管彩色多普勒评估阻塞性病变
Ultrasound Med Biol. 1995;21(8):1021-8. doi: 10.1016/0301-5629(95)00050-2.
4
Enhancement of Doppler flow signals in the left heart chambers by intravenous injection of sonicated albumin.静脉注射超声处理的白蛋白增强左心室内的多普勒血流信号。
J Am Coll Cardiol. 1993 Mar 1;21(3):737-42. doi: 10.1016/0735-1097(93)90107-c.
5
[Contrast-color Doppler echocardiography. Improved right heart diagnosis following intravenous injection of Echovist].[对比色多普勒超声心动图。静脉注射超声造影剂(Echovist)后右心诊断的改善]
Z Kardiol. 1989 Feb;78(2):101-8.
6
Amplitude information from Doppler color flow mapping systems: a preliminary study of the power mode.
J Am Coll Cardiol. 1991 Oct;18(4):997-1003. doi: 10.1016/0735-1097(91)90759-3.
7
Improvement of transthoracic pulmonary venous flow Doppler signal with intravenous injection of sonicated albumin.经静脉注射超声处理的白蛋白后经胸肺静脉血流多普勒信号的改善
J Am Coll Cardiol. 1995 Dec;26(7):1741-6. doi: 10.1016/0735-1097(95)00378-9.
8
Enhancement of mitral regurgitation and normal left atrial color Doppler flow signals with peripheral venous injection of a saccharide-based contrast agent.
J Am Coll Cardiol. 1993 Aug;22(2):521-8. doi: 10.1016/0735-1097(93)90059-a.
9
In vitro methods for studying the accuracy of velocity determination and spatial resolution of a color Doppler flow mapping system.用于研究彩色多普勒血流成像系统速度测定准确性和空间分辨率的体外方法。
Am Heart J. 1987 Jul;114(1 Pt 1):152-8. doi: 10.1016/0002-8703(87)90319-x.
10
Quantitative characterization of color Doppler images: reproducibility, accuracy, and limitations.彩色多普勒图像的定量表征:可重复性、准确性及局限性。
J Clin Ultrasound. 1995 Nov-Dec;23(9):537-50. doi: 10.1002/jcu.1870230906.

引用本文的文献

1
Developments in cardiovascular ultrasound: Part 1: Signal processing and instrumentation.心血管超声的发展:第1部分:信号处理与仪器设备
Med Biol Eng Comput. 1997 Nov;35(6):561-9. doi: 10.1007/BF02510961.
2
History of echocardiographic contrast agents.超声心动图造影剂的历史。
Clin Cardiol. 1997 Oct;20(10 Suppl 1):I7-11. doi: 10.1002/clc.4960201304.
3
Contrast echocardiography 1996. A review.1996年的超声心动图造影。综述。
Tex Heart Inst J. 1996;23(2):90-7.