Suppr超能文献

训练和校准后颞下颌系统肌肉和关节触诊检查者表现的可重复性。

Reproducibility of examiner performance for muscle and joint palpation in the temporomandibular system following training and calibration.

作者信息

Goulet J P, Clark G T, Flack V F

机构信息

Faculty of Dentistry, Department of Oral Medicine, Laval University, Canada.

出版信息

Community Dent Oral Epidemiol. 1993 Apr;21(2):72-7. doi: 10.1111/j.1600-0528.1993.tb00724.x.

Abstract

The purpose of this investigation was to assess examiner ability to consistently perform specific tasks related to muscle and joint palpation. Four trained and calibrated examiners were asked 1) to deliver index finger pressures within a high (1.5-2.1 kg) and low (0.5-1.1 kg) target pressure range and 2) to precisely locate one joint palpation and four muscle sites. After passing a calibration test, the performance of the examiners was monitored during the course of a replicability study assessing the consistency of clinical findings during repeated exams for TM disorders. (1) Index finger pressure was regularly tested over a 3-month period with a hand held pressure algometer, and the reading of each trial was recorded. Data analysis showed a high proportion of trials within the pressure range (overall 89.5%). Examiner performance across target range of pressures was statistically different for success rate and mean pressure delivered. The differences in the mean finger pressure delivered by each examiner (intraexaminer variation) was low and varied from 0.12 to 0.22 kg/cm2 for the desired range of pressures. (2) Paired examiners were asked to independently and sequentially mark palpation sites over the forehead, superficial and deep masseter, anterior temporalis, and lateral capsule of the temporomandibular joint. Replicability of site locations was assessed by measuring, with a boley gauge, the distance between sites selected by the paired examiners. Except for the superficial masseter and the anterior temporalis, the paired examiners selected palpation sites within a distance of 7 mm more than 85% of the time.(ABSTRACT TRUNCATED AT 250 WORDS)

摘要

本研究的目的是评估检查者持续执行与肌肉和关节触诊相关的特定任务的能力。四名经过培训且校准的检查者被要求:1)在高(1.5 - 2.1千克)和低(0.5 - 1.1千克)目标压力范围内施加食指压力;2)精确定位一个关节触诊点和四个肌肉部位。在通过校准测试后,在一项评估颞下颌关节紊乱症重复检查期间临床发现一致性的可重复性研究过程中,对检查者的表现进行监测。(1)在3个月的时间里,使用手持式压力测力计定期测试食指压力,并记录每次测试的读数。数据分析显示,压力范围内的测试比例很高(总体为89.5%)。检查者在目标压力范围内的表现,在成功率和施加的平均压力方面存在统计学差异。每位检查者施加的平均手指压力差异(检查者内变异)较低,在所需压力范围内为0.12至0.22千克/平方厘米。(2)要求配对的检查者独立且依次在前额、浅层和深层咬肌、颞肌前部以及颞下颌关节外侧囊上标记触诊部位。通过用游标卡尺测量配对检查者所选部位之间的距离,评估部位定位的可重复性。除了浅层咬肌和颞肌前部外,配对检查者在超过85%的时间里所选触诊部位的距离在7毫米以内。(摘要截断于250字)

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验