Transcutaneous oxygen monitoring for predicting skin viability in dogs.

作者信息

Rochat M C, Pope E R, Payne J T, Pace L W, Wagner-Mann C C

机构信息

Department of Veterinary Medicine, College of Veterinary Medicine, University of Missouri, Columbia 65211.

出版信息

Am J Vet Res. 1993 Mar;54(3):468-75.

PMID:8498754
Abstract

Transcutaneous oxygen (PO2-TC) monitoring is commonly used in human medicine for evaluating skin viability. The application of transcutaneous monitoring for evaluating skin viability in dogs was investigated. The changes in PO2-TC values were measured from 16 avascular skin flaps created along the lateral hemithoraces of 4 dogs. Transcutaneous oxygen values were serially recorded from the vascular base and avascular apex of each flap for 12 hours after surgery. A single transcutaneous measurement was obtained from each flap base and apex 24 hours after surgery. Serial arterial blood gas analyses were obtained to compare central oxygen values with PO2-TC values. Full-thickness skin biopsy specimens were harvested from the base and apex of each flap 24 hours after surgery. The flaps were observed for 4 days and then excised for histologic examination. A subjective grading scale was used to assess histologic changes. Throughout the 12-hour period and at 24 hours, a statistically significant difference was found between the PO2-TC values for apices and bases of the flaps. The mean PO2-TC for all bases was 90.9 mm of Hg +/- 3.3 SEM, and the mean PO2-TC for all apices was 21.2 mm of Hg +/- 1.8 SEM. The mean regional perfusion index (apex PO2-TC/base PO2-TC) was 0.23 +/- 0.02. The subjective numbers assigned to the biopsy specimens were statistically evaluated by using a paired Student's t test and a Wilcoxon signed-rank test. A significant difference was found between the numbers for the collective bases and apices with both tests.(ABSTRACT TRUNCATED AT 250 WORDS)

摘要

经皮氧分压(PO2-TC)监测在人类医学中常用于评估皮肤活力。本研究探讨了经皮监测在评估犬皮肤活力中的应用。在4只犬的侧半胸壁制作了16个无血管皮瓣,测量其PO2-TC值的变化。术后12小时,从每个皮瓣的血管蒂和无血管顶端连续记录经皮氧值。术后24小时,从每个皮瓣的蒂部和顶端各进行一次经皮测量。同时进行连续动脉血气分析,以比较中心氧值和PO2-TC值。术后24小时,从每个皮瓣的蒂部和顶端采集全层皮肤活检标本。观察皮瓣4天,然后切除进行组织学检查,使用主观评分量表评估组织学变化。在整个12小时期间及24小时时,皮瓣顶端和蒂部的PO2-TC值存在统计学显著差异。所有蒂部的平均PO2-TC为90.9 mmHg±3.3标准误,所有顶端的平均PO2-TC为21.2 mmHg±1.8标准误。平均区域灌注指数(顶端PO2-TC/蒂部PO2-TC)为0.23±0.02。使用配对学生t检验和Wilcoxon符号秩检验对活检标本的主观评分进行统计学评估。两种检验均显示,总体蒂部和顶端的评分存在显著差异。(摘要截断于250字)

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验