Miller H, Milk R, Diaz-Mitoma F
Regional Virology Laboratory, Children's Hospital of Eastern Ontario, Ottawa, Canada.
J Clin Microbiol. 1993 May;31(5):1336-8. doi: 10.1128/jcm.31.5.1336-1338.1993.
The sensitivity and accuracy of the VIDAS RSV assay in testing fresh specimens were 82.7 and 87.1%, respectively, whereas specimens previously frozen at -70 degrees C gave a sensitivity of 96.2% and an accuracy of 95.4%. The sensitivity and accuracy of Abbott Testpack RSV were 92.6 and 91.3% for fresh specimens and 86.8 and 88.1% for frozen specimens. The advantages and drawbacks of the two assays are discussed.