使用微球法和Patlak图分析法通过N-13氨PET评估冠状血管扩张储备。

Assessment of coronary vasodilator reserve by N-13 ammonia PET using the microsphere method and Patlak plot analysis.

作者信息

Tadamura E, Tamaki N, Yonekura Y, Kudoh T, Magata Y, Torizuka T, Tateno M, Nohara R, Sasayama S, Konishi J

机构信息

Department of Nuclear Medicine, Kyoto University Faculty of Medicine, Japan.

出版信息

Ann Nucl Med. 1995 Aug;9(3):109-18. doi: 10.1007/BF03165036.

Abstract

UNLABELLED

Noninvasive quantification of regional myocardial blood flow (MBF) has been successfully achieved with N-13 ammonia. The microsphere method as a simple method for quantifying regional myocardial blood flow was reevaluated in comparison with Patlak graphical analysis. In addition coronary vasodilator reserve (CVR) was estimated by both methods.

METHODS

Dynamic N-13 ammonia PET studies were performed in 10 healthy volunteers and 10 patients with coronary artery disease at baseline and after dipyridamole infusion (0.56 mg/kg). MBF was estimated by the microsphere method at various times and by Patlak graphical analysis. In order to reduce the noise level in the microsphere method, MBF estimates were also performed after data in 10-40 seconds were averaged.

RESULTS

In the studies on normal subjects MBF (ml/min/g) determined by the microsphere method significantly differs from time to time. However, MBF determined by the modified microsphere method [with average (Extraction fraction) x MBF values obtained between 100 and 120 sec] linearly correlated well with MBF by Patlak graphical analysis (r = 0.97, slope = 0.98, intercept = 0.20). In the studies on patients with coronary artery disease a good agreement of the MBF estimates was also observed (r = 0.97, slope = 0.98, intercept = 0.22). In the studies on the normal subjects and patients with coronary artery disease, CVR obtained by the modified microsphere method after correcting the overestimated MBF values also correlated well with that by Patlak graphical analysis (r = 0.90, slope = 1.14, intercept = -0.15, and r = 0.92, slope = 0.82, intercept = 0.25, respectively).

CONCLUSION

The modified microsphere method is a very simple and reliable approach for quantifying MBF with N-13 ammonia PET which is comparable to Patlak graphical analysis. It also makes possible CVR assessment as accurate as Patlak graphical analysis.

摘要

未标记

用N-13氨已成功实现区域心肌血流量(MBF)的无创定量。与Patlak图形分析相比,重新评估了微球法作为一种定量区域心肌血流量的简单方法。此外,两种方法都对冠状动脉扩张储备(CVR)进行了估计。

方法

对10名健康志愿者和10名冠心病患者在基线时以及静脉注射潘生丁(0.56mg/kg)后进行动态N-13氨PET研究。通过微球法在不同时间估计MBF,并通过Patlak图形分析进行估计。为了降低微球法中的噪声水平,在对10 - 40秒的数据进行平均后也进行了MBF估计。

结果

在对正常受试者的研究中,通过微球法测定的MBF(ml/min/g)随时间显著不同。然而,通过改良微球法[用100至120秒之间获得的平均(提取分数)×MBF值]测定的MBF与通过Patlak图形分析测定的MBF线性相关性良好(r = 0.97,斜率 = 0.98,截距 = 0.20)。在对冠心病患者的研究中,也观察到MBF估计值有良好的一致性(r = 0.97,斜率 = 0.98,截距 = 0.22)。在对正常受试者和冠心病患者的研究中,在校正高估的MBF值后,通过改良微球法获得的CVR与通过Patlak图形分析获得的CVR也相关性良好(分别为r = 0.90,斜率 = 1.14,截距 = -0.15,以及r = 0.92,斜率 = 0.82,截距 = 0.25)。

结论

改良微球法是一种用N-13氨PET定量MBF的非常简单且可靠的方法,与Patlak图形分析相当。它还使得CVR评估能够像Patlak图形分析一样准确。