Strength and setting behavior of resin-modified glass ionomer cements.

作者信息

Li J, von Beetzen M, Sundström F

机构信息

Department of Prosthodontics, Karolinska Institute, Huddinge, Sweden.

出版信息

Acta Odontol Scand. 1995 Oct;53(5):311-7. doi: 10.3109/00016359509005993.

Abstract

Diametral tensile strength (DTS), fracture strength, and Vickers microhardness were tested in three resin-modified glass ionomer cements (GICs), one chemically set GIC, and one dental composite. For the DTS studies test discs were immersed in deionized water at 37 degrees C for 10 min, 1 day, and 28 days, respectively. Cured discs were also implanted in back muscles of rats for 28 days before testing. The effects of light irradiation time and delayed curing on the DTS of the cements were also studied. Significantly higher strength was observed in the resin-modified GICs in comparison with the chemically set GIC at all observation period. K71 showed the highest strength among the GICs. No strength reductions were detected after 28 days for the specimens in vivo. An illumination time of 20 sec was enough to obtain final strength in the PFA and K71 specimens, and 40 sec was needed in the VI specimens. The strength of the resin-modified GICs when light-cured was significantly higher than when the same cements were allowed to set without irradiation. The microhardness of the light-cured GICs was similar to that of the dental composite. Considering the improved fracture strength and surface hardness, it was concluded that the resin-modified GICs present an interesting material for further development.

摘要

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验