Capello E, Gardella M, Leandri M, Abbruzzese G, Minatel C, Tartaglione A, Battaglia M, Mancardi G L
Dipartimento di Scienze Neurologiche e CNR, Università di Genova, Italy.
Ital J Neurol Sci. 1995 Nov;16(8):533-9. doi: 10.1007/BF02282911.
A cooling system (Mark VII Microclimate System) was used to give six thermosensitive multiple sclerosis patients two 45-minute daily coolings for a period of one month. Before the first cooling, a baseline clinical and electrophysiological examination was performed. The same tests were repeated after the first application and after the thirtieth cooling day, thus providing information relating to acute and chronic efficacy. A clinical improvement was observed after both acute and, more unexpectedly, chronic cooling, whereas a significant improvement in central somatosensory conduction was recorded only under acute conditions. Our data suggest that cooling with this device leads to an improvement in some functional performances (mainly fatigue and strength) of about two hours' duration in thermosensitive patients.
使用一种冷却系统(Mark VII微气候系统),让6名对温度敏感的多发性硬化症患者每天进行两次45分钟的冷却,持续一个月。在第一次冷却前,进行了基线临床和电生理检查。在第一次应用后以及第三十天冷却后重复相同测试,从而提供有关急性和慢性疗效的信息。在急性冷却后,更出乎意料的是在慢性冷却后均观察到临床改善,而仅在急性条件下记录到中枢体感传导有显著改善。我们的数据表明,使用该设备进行冷却可使温度敏感患者的某些功能表现(主要是疲劳和力量)改善约两小时。