At two german garbage sorting facilities, germ concentrations in the air were analyzed at different working environments (waste reception, manual sorting). At plant A, maximum concentrations of total bacteria (14700 CFU/m3), gram-negative bacteria (7279 CFU/m3) and moulds (> 84806 CFU/m3) occurred in the air at the final manual sorting belts. Referring to concentrations of total bacteria and moulds, concentrations in the air at the final sorting belts were significantly higher (p < 0.001) than at the other working environments. At plant B, the counts of total bacteria reached 7173 CFU/m3 in the air at the waste reception site and 5512 CFU/m3 at the manual sorting belt. Maximum concentrations for gram-negative bacteria were 247 resp. 206 CFU/m3 and 70919 resp. 60848 CFU/m3 for moulds. At the waste reception site, the aerial concentrations of total bacteria lay highly significantly (p < 0.001) and of moulds significantly (p < 0.05) above aerial concentrations at the manual sorting belt. As causes, an intensive mechanical pretreatment of recycle material at plant A and whirling up of sedimentary dust of the floor during manual sweeping of the material on to the transportation at plant B are discussed.
在两家德国垃圾分拣设施中,对不同工作环境(垃圾接收、人工分拣)下空气中的微生物浓度进行了分析。在工厂A,最终人工分拣传送带处空气中的总细菌(14700 CFU/m³)、革兰氏阴性菌(7279 CFU/m³)和霉菌(> 84806 CFU/m³)的浓度最高。就总细菌和霉菌的浓度而言,最终分拣传送带处空气中的浓度显著高于(p < 0.001)其他工作环境。在工厂B,垃圾接收处空气中的总细菌数达到7173 CFU/m³,人工分拣传送带处为5512 CFU/m³。革兰氏阴性菌的最高浓度分别为247和2百零6 CFU/m³,霉菌的最高浓度分别为70919和60848 CFU/m³。在垃圾接收处,空气中总细菌的浓度极显著高于(p < 0.001)人工分拣传送带处,霉菌的浓度显著高于(p < 0.05)人工分拣传送带处。文中讨论了造成这种情况的原因,在工厂A是回收材料的强化机械预处理,在工厂B是在将物料人工清扫到运输工具上时地面沉积灰尘的扬起。