Ozker K, Collier B D, Hellman R S, Isitman A T, Krasnow A Z, Uzum F, Steffel F S
Division of Nuclear Medicine, Medical College of Wisconsin, Milwaukee 53226, USA.
Nucl Med Commun. 1996 Apr;17(4):342-5. doi: 10.1097/00006231-199604000-00162.
99Tcm-hexamethylpropyleneamine oxime (99Tcm-HMPAO) is presently recognized as an effective radiopharmaceutical for in vitro white blood cell (WBC) labelling in addition to its widespread utility in cerebral blood flow imaging. While performing clinical studies in patients with a wide range of inflammatory diseases, the effect of the ligand and stannous ion quantity on the labelling efficiency (LE) of WBC was examined. A mean LE of 64 +/- 7% (n = 29) was achieved when the whole HMPAO kit was used for labelling. The LEs were 78 +/- 5% (n = 43), 83 +/- 3% (n = 37) and 85 +/- 5% (n = 18) when one-half, one-third and one-fifth of the lyophilized kit was used, respectively. This is in agreement with the reports of Sampson et al. and Lang et al., suggesting that the optimal formulation of the 99Tcm-HMPAO is a faction of the whole kit. Accordingly, fractionation of a freshly prepared 99Tcm-HMPAO kit into five parts for a high-efficiency WBC labelling is proposed, encouraging the more widespread use of 99Tcm-HMPAO in WBC labelling.
99锝-六甲基丙烯胺肟(99Tcm-HMPAO)除了在脑血流成像中有广泛应用外,目前还被认为是一种用于体外白细胞(WBC)标记的有效放射性药物。在对患有多种炎症性疾病的患者进行临床研究时,研究了配体和亚锡离子量对白细胞标记效率(LE)的影响。当使用整个HMPAO试剂盒进行标记时,平均标记效率为64±7%(n = 29)。当分别使用冻干试剂盒的二分之一、三分之一和五分之一时,标记效率分别为78±5%(n = 43)、83±3%(n = 37)和85±5%(n = 18)。这与桑普森等人和朗等人的报告一致,表明99Tcm-HMPAO的最佳配方是整个试剂盒的一部分。因此,建议将新制备的99Tcm-HMPAO试剂盒分成五份用于高效白细胞标记,这将促使99Tcm-HMPAO在白细胞标记中得到更广泛的应用。