Suppr超能文献

人体中缺氧与二氧化碳引起的呼吸反射性交替之间的关系。

The relation between hypoxia and CO2-induced reflex alternation of breathing in man.

作者信息

Ward S A, Cunningham D J

出版信息

Respir Physiol. 1977 May;29(3):363-78. doi: 10.1016/0034-5687(77)90010-x.

Abstract

Four healthy young volunteers, selected for the responsiveness and steadiness of their breathing, were studied in rest and mild exercise while receiving alternate inspirates of low and high PCO2 (0 and 8.6 kPa). PACO2, oscillated between ca. 6 and 7.5 kPa (45-55 torr). PAO2 was held steady at 4-7 levels between 6 and 28 kPa (45-210 torr). Thirteen separate inspiratory and expiratory variables (volumes, times, flows) were recorded and tested for reflex alternation. Matched controls were performed. Responses were generally small in relation to the scatter. Reflex alternation of any one variable was not always evident. The incidences of the responses were, in descending order, inspiratory flows and volumes, expiratory flows and volumes, expiratory duration; inspiratory duration alternated seldom, and then with only small amplitude. Reflex alternation was more likely to be observed in hypoxia than in euoxia or hyperoxia. A tendency for the incidences to be greater in exercise than at rest was not significant, but the amplitudes of alternation showed a significant difference in favour of exercise. In a substantial minority of experiments the amplitude of reflex alternation was significantly and positively correlated with hypoxia (1/(PAO2--C)). Alternation also occurred frequently in another substantial minority of experiments in which, however, there was no significant amplitude-hypoxia correlation. It was concluded that these two groups probably differed not so much in the form of the amplitude-hypoxia relation as in respect of the extent of the scatter in the observations. The results are consistent with interaction of non-steady-state with steady-state signals at the arterial chemoreceptors.

摘要

选取了4名呼吸反应灵敏且稳定的健康青年志愿者,在静息状态和轻度运动时接受低和高PCO₂(0和8.6 kPa)交替吸入的情况下进行研究。PACO₂在约6至7.5 kPa(45 - 55托)之间振荡。PAO₂维持在6至28 kPa(45 - 210托)之间的4 - 7个水平。记录了13个单独的吸气和呼气变量(容积、时间、流量),并测试其反射性交替变化。进行了配对对照。与离散度相比,反应通常较小。任何一个变量的反射性交替变化并不总是明显的。反应发生率从高到低依次为吸气流量和容积、呼气流量和容积、呼气持续时间;吸气持续时间很少交替变化,且幅度很小。与常氧或高氧相比,在低氧状态下更易观察到反射性交替变化。运动时反应发生率高于静息时的趋势并不显著,但交替变化的幅度在运动时显著更大。在相当一部分实验中,反射性交替变化的幅度与低氧(1/(PAO₂ - - C))显著正相关。在另一相当一部分实验中也频繁出现交替变化,然而,这些实验中幅度与低氧并无显著相关性。得出的结论是,这两组实验在幅度 - 低氧关系的形式上差异可能不大,而在于观察结果离散度的程度。这些结果与动脉化学感受器处非稳态信号与稳态信号的相互作用一致。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验