Kienle A, Patterson M S
Department of Medical Physics, Hamilton Regional Cancer Centre, Ontario, Canada.
Phys Med Biol. 1996 Oct;41(10):2221-7. doi: 10.1088/0031-9155/41/10/026.
We describe a fast, accurate method for determination of the optical coefficients of 'semi-infinite' and 'infinite' turbid media. For the particular case of time-resolved reflectance from a biological medium, we show that a single Monte Carlo simulation can be used to fit the data and to derive the absorption and reduced scattering coefficients. Tests with independent Monte Carlo simulations showed that the errors in the deduced absorption and reduced scattering coefficients are smaller than 1% and 2%, respectively.