Suppr超能文献

The risk of infection of three synthetic materials used in rectopexy with or without colonic resection for rectal prolapse.

作者信息

Athanasiadis S, Weyand G, Heiligers J, Heumuller L, Barthelmes L

机构信息

Department of Coloproctology, St. Joseph Hospital Duisburg Laar, Germany.

出版信息

Int J Colorectal Dis. 1996;11(1):42-4. doi: 10.1007/BF00418855.

Abstract

The incidence of infection was compared after the use of synthetic implants in abdominal rectopexy with (145 patients) and without (77 patients) synchronous colon resection. Three different materials were used, including polyvinyl alcohol (Ivalon) (n = 87), polyglactin (Vicryl) mesh (n = 109), and Gore-Tex (n = 26). In patients have colonic resection two (3.7%) pelvic infections occurred in the polyvinyl alcohol (Ivalon) group, one abdominal infection with polyglactin (Vicryl) and none with Gore-Tex. In the group without colonic resection, two patients (3.0%) developed infection after polyvinyl alcohol (Ivalon) insertion with one occurring after polyglactin (Vicryl) or Gore-Tex. Overall mortality was 0.4%. Follow-up ranged from 3 to 120 months. There were 3 (1.9%) cases of recurrent prolapse in 151 patients with full-thickness rectal prolapse.