Kotter R W
Neonatal Netw. 1996 Sep;15(6):43-7.
The purpose of this study was to determine whether normal saline (NS) is as effective as 10 units heparin/ml saline (HS) in maintaining patency of intermittent intravenous devices (i.v. locks) in neonates. We conducted a prospective, double-blind, randomized study of 118 24-gauge catheters used exclusively as i.v. locks and removed consequent to catheter failure. Subjects were infants, including premature infants, less than one month of age, admitted to a Level II NICU. Catheters were observed for length of patency as well as incidence of phlebitis, occlusion, infiltration, and leaking. There was no statistically significant difference in average duration of patency between NS-flushed catheters and HS-flushed catheters. Phlebitis, occlusion, infiltration, and leaking occurred with equal frequency for both solutions.
本研究的目的是确定生理盐水(NS)在维持新生儿间歇性静脉输液装置(静脉留置针)通畅方面是否与每毫升含10单位肝素的生理盐水(HS)同样有效。我们对118根专门用作静脉留置针且因导管故障而拔除的24号导管进行了一项前瞻性、双盲、随机研究。研究对象为入住二级新生儿重症监护病房(NICU)的年龄小于1个月的婴儿,包括早产儿。观察导管的通畅时长以及静脉炎、堵塞、渗漏和浸润的发生率。用NS冲洗的导管与用HS冲洗的导管在平均通畅持续时间上无统计学显著差异。两种溶液引起静脉炎、堵塞、渗漏和浸润的频率相同。