计算机断层扫描中的图像质量与剂量。

Image quality and dose in computed tomography.

作者信息

Jurik A G, Jessen K A, Hansen J

机构信息

Department of Radiology, Municipal Hospital, University Hospital of Aarhus, Noerrebrogade 44, DK-8000 Aarhus C, Denmark.

出版信息

Eur Radiol. 1997;7(1):77-81. doi: 10.1007/s003300050114.

Abstract

Radiation exposure to the patient during CT is relatively high, and it is therefore important to optimize the dose so that it is as low as possible but still consistent with required diagnostic image quality. There is no established method for measuring diagnostic image quality; therefore, a set of image quality criteria which must be fulfilled for optimal image quality was defined for the retroperitoneal space and the mediastinum. The use of these criteria for assessment of image quality was tested based on 113 retroperitoneal and 68 mediastinal examinations performed in seven different CT units. All the criteria, except one, were found to be usable for measuring diagnostic image quality. The fulfillment of criteria was related to the radiation dose given in the different departments. By examination of the retroperitoneal space the effective dose varied between 5.1 and 20.0 mSv (milli Sievert), and there was a slight correlation between dose and high percent of "yes" score for the image quality criteria. For examination of the mediastinum the dose range was 4.4-26.5 mSv, and there was no significant increment of image quality at high doses. The great variation of dose at different CT units was due partly to differences regarding the examination procedure, especially the number of slices and the mAs (milli ampere second), but inherent dose variation between different scanners also played a part.

摘要

在CT检查过程中,患者所接受的辐射剂量相对较高,因此优化剂量非常重要,要使其尽可能低,但仍要符合所需的诊断图像质量要求。目前尚无既定的方法来测量诊断图像质量;因此,针对腹膜后间隙和纵隔,定义了一组为实现最佳图像质量必须满足的图像质量标准。基于在七个不同CT设备上进行的113例腹膜后检查和68例纵隔检查,测试了使用这些标准评估图像质量的情况。结果发现,除一项标准外,所有标准均可用于测量诊断图像质量。标准的满足情况与不同科室所给予的辐射剂量有关。通过对腹膜后间隙的检查,有效剂量在5.1至20.0毫希沃特之间变化,剂量与图像质量标准中“是”评分的高百分比之间存在轻微相关性。对于纵隔检查,剂量范围为4.4 - 26.5毫希沃特,高剂量时图像质量无显著提高。不同CT设备的剂量差异很大,部分原因是检查程序不同,尤其是切片数量和毫安秒,但不同扫描仪之间固有的剂量差异也起到了一定作用。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验