Suppr超能文献

使用宫颈夹双螺母双瓣窥器进行输卵管精子灌注的简单方法治疗不明原因不孕症的妊娠率更高:一项前瞻性随机研究。

Higher pregnancy rates with a simple method for fallopian tube sperm perfusion, using the cervical clamp double nut bivalve speculum in the treatment of unexplained infertility: a prospective randomized study.

作者信息

Mamas L

机构信息

Mitera Maternity and Surgical Hospital, Athens, Greece.

出版信息

Hum Reprod. 1996 Dec;11(12):2618-22. doi: 10.1093/oxfordjournals.humrep.a019181.

Abstract

The object of this study was to evaluate the efficacy of the newly developed cervical clamp double nut bivalve (DNB) speculum used for Fallopian tube sperm perfusion (FSP) with 4 ml of the inseminate, in comparison with standard intrauterine insemination (IUI) using a volume of 0.5 ml of the inseminate. Couples with unexplained infertility (n = 104), undergoing 202 cycles, were enrolled in this study. Cycles were assigned randomly to either IUI (group A, n = 92) or FSP + DNB speculum (group B, n = 110). Ovarian stimulation was achieved using three different ovarian stimulation protocols in both groups. The age and follicular development of the patients were similar in both groups. The serum hormonal measurements and the endometrial thickness was also similar on the day of human chorionic gonadotrophin (HCG) administration. The mean (+/-SD) number of motile spermatozoa inseminated was 44.83 +/- 16.57 x 10(6) in group A and 42.68 +/- 13.44 x 10(6) in group B. In group A (IUI). 11 clinical pregnancies (presence of gestational sac with heart beats) occurred (11.95% per cycle). In group B (FSP + DNB speculum) 29 clinical pregnancies occurred (26.36% per cycle). These differences were statistically significant (P < 0.001). The results of this study for the treatment of unexplained infertility indicate that this simple, well tolerated, inexpensive method of using the DNB speculum for FSP is more successful than standard IUI.

摘要

本研究的目的是评估新开发的宫颈钳双螺母双瓣(DNB)窥器用于输卵管内精子灌注(FSP)(注入4毫升授精液)的疗效,并与使用0.5毫升授精液的标准宫内授精(IUI)进行比较。纳入了104对原因不明的不孕夫妇,共进行202个周期。这些周期被随机分配到IUI组(A组,n = 92)或FSP + DNB窥器组(B组,n = 110)。两组均采用三种不同的卵巢刺激方案进行卵巢刺激。两组患者的年龄和卵泡发育情况相似。在注射人绒毛膜促性腺激素(HCG)当天,血清激素测量值和子宫内膜厚度也相似。A组注入的活动精子平均数量(±标准差)为44.83±16.57×10⁶,B组为42.68±13.44×10⁶。在A组(IUI)中,发生了11例临床妊娠(有心跳的妊娠囊)(每个周期11.95%)。在B组(FSP + DNB窥器)中,发生了29例临床妊娠(每个周期26.36%)。这些差异具有统计学意义(P < 0.001)。本研究对于原因不明的不孕症治疗结果表明,这种使用DNB窥器进行FSP的简单、耐受性良好且廉价的方法比标准IUI更成功。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验