Nesje M, Flåøyen A, Moe L
Department of Reproduction and Forensic Medicine, Norwegian College of Veterinary Medicine, Oslo, Norway.
Vet Res Commun. 1997 Jan;21(1):29-35. doi: 10.1023/b:verc.0000009698.28252.d1.
The aim of the study was to establish reference values for glomerular filtration rate (GFR) in healthy sheep from the clearance of iohexol in serum. Fifteen healthy sheep were tested twice with 14 to 21 days between tests. No side-effects were observed after iohexol injections and all the sheep were clinically normal during and after the study. The mean clearance of iohexol estimated by the two-compartment method was 1.8 ml/min per kg (95% CI = 1.6-2.0) in the first trial and 1.7 ml/min per kg (1.5-1.9) in the second trial. The mean GFRiohexol estimated by a one-compartment method was 1.9 ml/min per kg (1.7-2.2) in the first trial and 1.8 ml/min per kg (1.6-2.0) in the second. The GFR values were similar to those reported for the inulin method. The results indicate that the iohexol method is valid for estimating GFR in sheep, and it is easier to perform than the inulin method.
本研究的目的是通过血清中碘海醇的清除率来确定健康绵羊肾小球滤过率(GFR)的参考值。15只健康绵羊接受了两次检测,两次检测间隔14至21天。注射碘海醇后未观察到副作用,并且所有绵羊在研究期间及之后临床均正常。在第一次试验中,用二室模型法估算的碘海醇平均清除率为1.8毫升/分钟/千克(95%置信区间=1.6 - 2.0),第二次试验中为1.7毫升/分钟/千克(1.5 - 1.9)。用一室模型法估算的第一次试验中碘海醇平均GFR为1.9毫升/分钟/千克(1.7 - 2.2),第二次试验中为1.8毫升/分钟/千克(1.6 - 2.0)。这些GFR值与用菊粉法报告的值相似。结果表明,碘海醇法可有效估算绵羊的GFR,并且比菊粉法更易于操作。