Suppr超能文献

全视野闪烁试验在慢性开角型青光眼早期诊断中的应用

The full-field flicker test in early diagnosis of chronic open-angle glaucoma.

作者信息

Horn F K, Jonas J B, Korth M, Jünemann A, Gründler A

机构信息

Department of Ophthalmology, Friedrich-Alexander-University Erlangen-Nürnberg, Germany.

出版信息

Am J Ophthalmol. 1997 Mar;123(3):313-9. doi: 10.1016/s0002-9394(14)70126-6.

Abstract

PURPOSE

To evaluate whether the full-field flicker test, a psychophysical test employing full-field flickering stimuli to measure temporal contrast sensitivity, can detect glaucomatous optic nerve damage in patients with increased intraocular pressure and glaucomatous optic disk abnormalities but normal visual fields.

METHODS

Temporal contrast sensitivity was determined with a sinusoidally flickering light (frequency, 37.1 Hz) of constant mean photopic luminance (10 cd/m2) presented in a full-field bowl of 58-cm diameter. The prospective study included three groups of individuals: the "preperimetric" glaucoma group of 80 patients with increased intraocular pressure, glaucomatous optic disk abnormalities, and normal visual fields; the "perimetric" glaucoma group of 56 glaucomatous patients with increased intraocular pressure and glaucomatous changes of the optic disk and visual field; and the control group of 96 normal subjects.

RESULTS

Temporal contrast sensitivity was significantly (P < .001) lower in the two glaucoma groups than in the control group. In the preperimetric glaucoma group, 34% of the patients (27/ 80) were recognized by the full-field flicker test at a specificity of 99%. For all study subjects, temporal contrast sensitivity decreased significantly (P < .001) with decreasing neuroretinal rim area, enlarging peripapillary atrophy, and diminishing retinal nerve fiber layer visibility.

CONCLUSIONS

The full-field flicker test can detect glaucomatous optic nerve damage in patients with increased intraocular pressure, glaucomatous optic disk abnormalities, and normal visual fields. Considering its feasibility, simplicity, quick performance, and low costs, the full-field flicker test may be helpful in clinics and in screening examinations as a supplement to glaucoma diagnosis.

摘要

目的

评估全视野闪烁试验,一种采用全视野闪烁刺激来测量时间对比敏感度的心理物理学测试,能否检测出眼压升高、存在青光眼性视盘异常但视野正常的患者的青光眼性视神经损伤。

方法

使用直径58厘米的全视野碗状装置呈现平均明视觉亮度恒定(10坎德拉/平方米)的正弦闪烁光(频率为37.1赫兹)来测定时间对比敏感度。前瞻性研究纳入三组个体:80例眼压升高、存在青光眼性视盘异常且视野正常的“视野检查前”青光眼组;56例眼压升高且存在视盘和视野青光眼性改变的青光眼“视野检查中”组;以及96名正常受试者组成的对照组。

结果

两个青光眼组的时间对比敏感度显著低于对照组(P <.001)。在视野检查前青光眼组中,全视野闪烁试验识别出34%的患者(27/80),特异性为99%。对于所有研究对象,随着神经视网膜边缘面积减小、视乳头周围萎缩扩大以及视网膜神经纤维层可见度降低,时间对比敏感度显著下降(P <.001)。

结论

全视野闪烁试验能够检测出眼压升高、存在青光眼性视盘异常且视野正常的患者的青光眼性视神经损伤。考虑到其可行性、简便性、快速性和低成本,全视野闪烁试验作为青光眼诊断的补充,可能在临床和筛查检查中发挥作用。