Suppr超能文献

对比增强腹部磁共振血管造影:通过自动检测造影剂到达主动脉来优化成像延迟时间。

Contrast-enhanced abdominal MR angiography: optimization of imaging delay time by automating the detection of contrast material arrival in the aorta.

作者信息

Prince M R, Chenevert T L, Foo T K, Londy F J, Ward J S, Maki J H

机构信息

Department of Radiology, University of Michigan, Ann Arbor 48109-0030, USA.

出版信息

Radiology. 1997 Apr;203(1):109-14. doi: 10.1148/radiology.203.1.9122376.

Abstract

PURPOSE

To improve gadolinium-enhanced magnetic resonance (MR) angiogram quality by automatically synchronizing acquisition of central k-space image data with the arterial phase of contrast material bolus infusion.

MATERIALS AND METHODS

A spin-echo pulse sequence with orthogonal 90 degrees and 180 degrees pulses was used to monitor signal in a single 4 x 4 x 12-cm voxel that encompassed a segment of aorta. An increase in signal that corresponded to the arrival of gadolinium was used to trigger three-dimensional, spoiled gradient-echo abdominal MR angiography in 50 adult patients.

RESULTS

Arterial signal intensity increased 28-fold with automatic compared to 19-fold with manual triggering (P < .05) at an approximate dose of 0.3 mmol/kg. Automatic triggering with a lower dose (approximately 0.2 mmol/kg) resulted in 20-fold arterial enhancement, which is comparable with enhancement after manual triggering at the high dose. In addition, venous enhancement was less (1.5-fold) with automatic than with manual (3.5-fold) triggering at the same dose (P < .05).

CONCLUSION

Automatic triggering results in improved arterial-tovenous contrast. It increases arterial enhancement or enables MR angiograms to be obtained with less contrast material. The authors now routinely use this technique for aortorenal imaging with a gadolinium-based contrast material dose of 20 mmol (40 mL) in patients who weigh more than 50 kg and 10 mmol (20 mL) in patients who weigh less than 50 kg.

摘要

目的

通过使中心k空间图像数据的采集与造影剂团注的动脉期自动同步,提高钆增强磁共振(MR)血管造影的质量。

材料与方法

使用具有正交90度和180度脉冲的自旋回波脉冲序列监测一个4×4×12厘米的单一体素中的信号,该体素包含主动脉的一段。与钆到达相对应的信号增加被用于触发50例成年患者的三维、扰相梯度回波腹部MR血管造影。

结果

在约0.3 mmol/kg的剂量下,自动触发时动脉信号强度增加28倍,而手动触发时增加19倍(P < 0.05)。较低剂量(约0.2 mmol/kg)的自动触发导致动脉增强20倍,与高剂量手动触发后的增强效果相当。此外,在相同剂量下,自动触发时静脉增强(1.5倍)低于手动触发(3.5倍)(P < 0.05)。

结论

自动触发可改善动静脉对比度。它增加了动脉增强,或者能够用更少的造影剂获得MR血管造影。作者现在常规使用该技术对体重超过50 kg的患者进行基于钆造影剂的腹主动脉肾动脉成像,剂量为20 mmol(40 mL),对体重低于50 kg的患者剂量为10 mmol(20 mL)。