Roth B J
Department of Physics and Astronomy, Vanderbilt University, Nashville, TN 37235, USA.
IEEE Trans Biomed Eng. 1997 Apr;44(4):326-8. doi: 10.1109/10.563303.
Electrical conductivities in the bidomain model of cardiac tissue are expressed as functions of four parameters. These expressions allow simulations to be performed using nominal, equal, and reciprocal anisotropy without introducing undesired effects, such as length constant variations. Relative values of the bidomain conductivities are estimated to be: sigma iL = 1, sigma iT = 0.1, sigma eL = 1, and sigma eT = 0.4.