Suppr超能文献

手指收缩压:冷刺激对对照手指的影响。

Finger systolic blood pressures: effects of cold provocation on the reference finger.

作者信息

Lindsell C J, Griffin M J

机构信息

Human Factors Research Unit, University of Southampton, U.K.

出版信息

Cent Eur J Public Health. 1995;3 Suppl:45-8.

PMID:9150968
Abstract

Finger systolic blood pressure measured after cold provocation and ischemia of a digit is used to assist in the diagnosis of vibration-induced white finger, VWF. A reduction in finger systolic blood pressure after cooling is assumed to indicate vascular dysfunction. The percentage pressure change observed in the tested finger is often corrected for whole body effects (systemic systolic pressure changes) according to the pressure change measured in a reference finger. The commonly used method of correction is based on assumptions as to the causes of any changes occurring in the reference finger. It is assumed that the reference finger is not differentially susceptible to the cold provocation of the test finger, arising from either close proximity to the cold provocation or from a vascular disorder in the reference finger. An experiment has been undertaken to investigate the repeatability, over three days, of measurements of the arm systolic pressures of both arms and the finger systolic pressures in air of four fingers of both hands. The systolic pressures of both arms and of four fingers of one hand were also measured whilst the fifth finger of the same hand was subjected to cold provocation at 10 degrees C. Twelve healthy male subjects were rested in a supine position for 15 minutes in a room at 21-24 degrees C before measurements were taken. Finger systolic blood pressures were recorded using strain gauge plethysmography. The results show that the systolic blood pressure measurements were generally repeatable, but differed with measurement location. Cold provocation of the test finger had little consistent effect on the systolic pressures measured at other locations. The results are interpreted with regard to the correction of finger systolic pressure using a reference measurement.

摘要

通过对手指进行冷激发和缺血后测量的手指收缩压,可用于辅助诊断振动性白指(VWF)。冷却后手指收缩压的降低被认为表明血管功能障碍。根据在对照手指中测量的压力变化,对测试手指中观察到的压力变化百分比进行全身效应(全身收缩压变化)校正。常用的校正方法基于对对照手指中发生的任何变化原因的假设。假设对照手指对测试手指的冷激发没有差异敏感性,这要么是由于靠近冷激发源,要么是由于对照手指的血管疾病。已经进行了一项实验,以研究双臂的手臂收缩压和双手四个手指在空气中的手指收缩压测量在三天内的重复性。在对同一只手的第五根手指进行10摄氏度的冷激发时,还测量了一只手臂和同一只手四个手指的收缩压。在测量前,12名健康男性受试者在21 - 24摄氏度的房间中仰卧休息15分钟。使用应变片体积描记法记录手指收缩压。结果表明,收缩压测量总体上是可重复的,但因测量位置而异。测试手指的冷激发对在其他位置测量的收缩压几乎没有一致的影响。根据使用对照测量对手指收缩压进行校正的情况对结果进行了解释。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验