Suppr超能文献

BACTEC 9240加需氧/F树脂瓶与隔离器需氧培养系统用于检测血流感染的临床比较。

Clinical comparison of BACTEC 9240 plus aerobic/F resin bottles and the isolator aerobic culture system for detection of bloodstream infections.

作者信息

Cockerill F R, Reed G S, Hughes J G, Torgerson C A, Vetter E A, Harmsen W S, Dale J C, Roberts G D, Ilstrup D M, Henry N K

机构信息

Department of Laboratory Medicine and Pathology, Mayo Clinic, Rochester, Minnesota 55905, USA.

出版信息

J Clin Microbiol. 1997 Jun;35(6):1469-72. doi: 10.1128/jcm.35.6.1469-1472.1997.

Abstract

The Plus Aerobic/F resin bottle of the BACTEC 9240 automated blood culture system (Becton Dickinson Diagnostic Instrument Systems, Sparks, Md.) was compared with aerobic culture of the Isolator system (Wampole Laboratories, Cranbury, N.J.) for the detection of bloodstream microorganisms from 6,145 blood cultures collected from adult patients with suspected septicemia. The BACTEC resin bottles were incubated for 7 days, and the sediment from the Isolator tube was inoculated to sheep blood and chocolate agars which were incubated for 72 h and to inhibitory mold, brain heart infusion, and Sabouraud agars which were incubated for 21 days. A total of 622 microorganisms were recovered from 583 blood cultures. The BACTEC resin bottle recovered statistically significantly more pathogens overall than the Isolator system (P = 0.0006). When individual pathogens isolated from either system for a 7-day study period were assessed, it was determined that the BACTEC resin bottle detected statistically significantly more isolates of Staphylococcus aureus (P = 0.0113) and coagulase-negative Staphylococcus spp. (P = 0.0029) than the Isolator system. The BACTEC resin bottle also detected statistically significantly more bloodstream infections (septic episodes) caused by coagulase-negative Staphylococcus spp. (P = 0.0146). The Isolator system recovered statistically significantly more contaminants overall (P < 0.0001), and among this group of microorganisms, recovered statistically significantly more Bacillus spp. (P < 0.0001), coagulase-negative Staphylococcus spp. (P < 0.0001), and viridans group Streptococcus spp. (P = 0.0156). The Isolator system detected statistically significantly more isolates of Histoplasma capsulatum (P = 0.004), but all of these isolates were detected at > or = 7 days of incubation of fungal plates, i.e., after the system to system comparison study period (7 days). In blood culture sets which produced growth of the same pathogen in both systems, there was a statistically significant difference in median time to detection for all pathogens combined favoring the BACTEC resin bottle over the Isolator tube (P < 0.05). When assessing individual microorganisms, the median times for detection of S. aureus, Enterococcus spp., and Pseudomonas spp. were all statistically significantly less for the BACTEC system (P < 0.05). The BACTEC instrument had 79 (1.3%) false positive signals. The BACTEC system required less processing time than the Isolator system and eliminates the hands-on time for detection of positive cultures required with the Isolator system.

摘要

将BACTEC 9240自动血培养系统(Becton Dickinson诊断仪器系统公司,马里兰州斯帕克斯)的Plus需氧/F树脂瓶与Isolator系统(Wampole实验室,新泽西州克兰伯里)的需氧培养进行比较,以检测从疑似败血症的成年患者采集的6145份血培养物中的血流微生物。将BACTEC树脂瓶孵育7天,将Isolator管中的沉淀物接种到绵羊血琼脂和巧克力琼脂上,孵育72小时,接种到抑制性霉菌、脑心浸液和沙氏琼脂上,孵育21天。从583份血培养物中总共分离出622株微生物。总体而言,BACTEC树脂瓶回收的病原体在统计学上显著多于Isolator系统(P = 0.0006)。在为期7天的研究期间,对从任一系统分离出的单个病原体进行评估时,确定BACTEC树脂瓶检测到的金黄色葡萄球菌(P = 0.0113)和凝固酶阴性葡萄球菌属菌株(P = 0.0029)在统计学上显著多于Isolator系统。BACTEC树脂瓶还检测到由凝固酶阴性葡萄球菌属菌株引起的血流感染(败血症发作)在统计学上显著更多(P = 0.0146)。Isolator系统总体回收的污染物在统计学上显著更多(P < 0.0001),在这组微生物中,回收的芽孢杆菌属菌株(P < 0.0001)、凝固酶阴性葡萄球菌属菌株(P < 0.0001)和草绿色链球菌属菌株(P = 0.0156)在统计学上显著更多。Isolator系统检测到的荚膜组织胞浆菌分离株在统计学上显著更多(P = 0.004),但所有这些分离株都是在真菌平板孵育≥7天时检测到的,即在系统间比较研究期(7天)之后。在两个系统中均培养出相同病原体的血培养组中,所有病原体合并的中位检测时间在统计学上存在显著差异,有利于BACTEC树脂瓶而非Isolator管(P < 0.05)。在评估单个微生物时,BACTEC系统检测金黄色葡萄球菌、肠球菌属和假单胞菌属的中位时间在统计学上均显著更短(P < 0.05)。BACTEC仪器有79个(1.3%)假阳性信号。BACTEC系统比Isolator系统所需的处理时间更少,并且消除了Isolator系统检测阳性培养物所需的人工操作时间。

相似文献

引用本文的文献

本文引用的文献

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验