The brain uses mostly dissolved oxygen during profoundly hypothermic cardiopulmonary bypass.

作者信息

Dexter F, Kern F H, Hindman B J, Greeley W J

机构信息

Department of Anesthesia, University of Iowa, Iowa City 52242, USA.

出版信息

Ann Thorac Surg. 1997 Jun;63(6):1725-9. doi: 10.1016/s0003-4975(97)00297-x.

DOI:10.1016/s0003-4975(97)00297-x
PMID:9205174
Abstract

BACKGROUND

During profoundly hypothermic cardiopulmonary bypass, cerebral venous oxygen saturation increases (eg, to 98% at 15 degrees C). We reanalyzed results of clinical studies to learn why.

METHODS

One hundred sixty-eight cerebral oxygen transport measurements were available from 96 infants and children undergoing profoundly hypothermic cardiopulmonary bypass during repair of congenital heart defects.

RESULTS

Dissolved oxygen accounted for 2% to 17% of arterial oxygen content, depending on the arterial oxygen partial pressure and hemoglobin concentration. The fraction of the cerebral metabolic rate for oxygen obtained from dissolved oxygen depended on pump flow, temperature, hemoglobin concentration, and arterial oxygen partial pressure (all p < 10(-3)). For "full-flow" cardiopulmonary bypass, temperatures less than 18 degrees C, and arterial oxygen partial pressure measurements more than 180 mm Hg, the mean +/- standard deviation of the fraction of cerebral metabolic rate for oxygen obtained from dissolved oxygen equaled 77% +/- 19%.

CONCLUSIONS

Dissolved oxygen satisfies most of the brain's oxygen requirements during profound hypothermic cardiopulmonary bypass. This result reflects four properties of profound hypothermic cardiopulmonary bypass: (1) increases in hemoglobin's oxygen affinity due to profound hypothermia (which impairs oxygen transfer from hemoglobin to cerebral tissue), (2) use of hemodilution, (3) use of high arterial oxygen partial pressure, and (4) low cerebral metabolic rate of oxygen.

摘要

相似文献

1
The brain uses mostly dissolved oxygen during profoundly hypothermic cardiopulmonary bypass.
Ann Thorac Surg. 1997 Jun;63(6):1725-9. doi: 10.1016/s0003-4975(97)00297-x.
2
A prospective, randomized comparison of cerebral venous oxygen saturation during normothermic and hypothermic cardiopulmonary bypass.常温与低温体外循环期间脑静脉血氧饱和度的前瞻性随机对照研究。
J Thorac Cardiovasc Surg. 1994 Apr;107(4):1020-8; discussion 1028-9.
3
Effect of pump flow rate on cerebral blood flow during hypothermic cardiopulmonary bypass in adults.成人低温体外循环期间泵流量对脑血流量的影响。
J Cardiothorac Vasc Anesth. 1997 Jun;11(4):415-9. doi: 10.1016/s1053-0770(97)90047-1.
4
Cerebral oxygenation during cardiopulmonary bypass in children.
J Thorac Cardiovasc Surg. 1997 Jan;113(1):71-8; discussion 78-9. doi: 10.1016/S0022-5223(97)70401-X.
5
Correlation between cerebral and mixed venous oxygen saturation during moderate versus tepid hypothermic hemodiluted cardiopulmonary bypass.中度与低温体外循环期间脑氧饱和度与混合静脉血氧饱和度之间的相关性
J Cardiothorac Vasc Anesth. 2006 Dec;20(6):819-25. doi: 10.1053/j.jvca.2005.04.015. Epub 2006 Jan 6.
6
Cerebral response to hemodilution during hypothermic cardiopulmonary bypass in adults.成人低温体外循环期间血液稀释的脑反应。
Anesth Analg. 1999 Nov;89(5):1078-83.
7
Theoretical analysis of cerebral venous blood hemoglobin oxygen saturation as an index of cerebral oxygenation during hypothermic cardiopulmonary bypass. A counterproposal to the "luxury perfusion" hypothesis.低温体外循环期间脑静脉血血红蛋白氧饱和度作为脑氧合指标的理论分析。对“过度灌注”假说的反驳。
Anesthesiology. 1995 Aug;83(2):405-12. doi: 10.1097/00000542-199508000-00021.
8
Tissue oxygenation with graded dissolved oxygen delivery during cardiopulmonary bypass.
J Thorac Cardiovasc Surg. 1995 Sep;110(3):774-85. doi: 10.1016/S0022-5223(95)70111-7.
9
pH-stat management reduces the cerebral metabolic rate for oxygen during profound hypothermia (17 degrees C). A study during cardiopulmonary bypass in rabbits.pH值稳态管理可降低深度低温(17摄氏度)期间的脑氧代谢率。一项针对兔体外循环的研究。
Anesthesiology. 1995 Apr;82(4):983-95; discussion 24A. doi: 10.1097/00000542-199504000-00023.
10
Hypothermic acid-base management does not affect cerebral metabolic rate for oxygen at 27 degrees C. A study during cardiopulmonary bypass in rabbits.低温酸碱管理对27摄氏度时的脑氧代谢率无影响。一项在兔体外循环期间进行的研究。
Anesthesiology. 1993 Sep;79(3):580-7. doi: 10.1097/00000542-199309000-00023.

引用本文的文献

1
Acid-base status of the blood contained in the cardiotomy reservoir during deep hypothermic circulatory arrest at 18 °C.18℃深低温循环停搏期间心脏手术储血器中血液的酸碱状态。
J Extra Corpor Technol. 2025 Sep;57(3):123-128. doi: 10.1051/ject/2025014. Epub 2025 Sep 15.
2
A safe and flexible cardiopulmonary bypass technique for complex aortic surgery without the requirement for deep hypothermic circulatory arrest.一种用于复杂主动脉手术的安全且灵活的体外循环技术,无需深低温停循环。
J Extra Corpor Technol. 2013 Dec;45(4):254-8.
3
A biochemical--biophysical study of hemoglobins from woolly mammoth, Asian elephant, and humans.
对来自猛犸象、亚洲象和人类的血红蛋白进行生物化学-生物物理研究。
Biochemistry. 2011 Aug 30;50(34):7350-60. doi: 10.1021/bi200777j. Epub 2011 Aug 2.
4
Relationship of intraoperative cerebral oxygen saturation to neurodevelopmental outcome and brain magnetic resonance imaging at 1 year of age in infants undergoing biventricular repair.在接受双心室修复的婴儿中,术中脑氧饱和度与 1 岁时神经发育结局和脑磁共振成像的关系。
Circulation. 2010 Jul 20;122(3):245-54. doi: 10.1161/CIRCULATIONAHA.109.902338. Epub 2010 Jul 6.
5
Hemodilution with liposome-encapsulated low-oxygen-affinity hemoglobin does not attenuate hypothermic cerebral ischemia in rats.脂质体包裹的低氧亲和力血红蛋白进行血液稀释并不能减轻大鼠低温性脑缺血。
J Artif Organs. 2005;8(4):263-9. doi: 10.1007/s10047-005-0309-9.
6
Effects of pH management during deep hypothermic bypass on cerebral oxygenation: alpha-stat versus pH-stat.深低温体外循环期间pH管理对脑氧合的影响:α稳态与pH稳态。
J Zhejiang Univ Sci. 2004 Oct;5(10):1290-7. doi: 10.1631/jzus.2004.1290.