Zouaoui A, Sahel M, Marro B, Clemenceau S, Dargent N, Bitar A, Faillot T, Capelle L, Marsault C
Department of Neuroradiology, Hopital de la Pitié, Paris, France.
Neurosurgery. 1997 Jul;41(1):125-30. doi: 10.1097/00006123-199707000-00026.
Three-dimensional computed tomographic angiography (CTA) is a recently developed imaging modality. We demonstrate the value of this noninvasive method in replacing digital subtraction angiography (DSA) in the detection of aneurysms of the circle of Willis in patients with subarachnoid hemorrhage admitted to our institution.
A helical acquisition was performed for computed tomographic scans obtained for 120 patients with a 1 mm per second table speed and a 1-mm collimation, 1:1 pitch. Axial source images were transferred on a console Advantage Windows workstation (General Electric, Milwaukee, WI) and CTA was obtained using maximum intensity projection reconstruction. All patients had undergone DSA of the circle of Willis (80 patients preoperatively and 40 postoperatively).
A total of 129 aneurysms were detected in 107 patients. Three-dimensional CTA disclosed nothing abnormal in 13 patients. Ninety-two patients sustained one aneurysm, 10 patients sustained two, 3 patients sustained three, and 2 patients sustained four. All results were confirmed by DSA. In two cases, aneurysms of the middle cerebral artery were defected by CTA but not by DSA. When using angiographic views, the aneurysm was always masked by a branch of the middle cerebral artery.
The sensitivity of three-dimensional CTA is comparable with that of DSA, and its specificity is 100%. Because CTA is simple, quick, noninvasive, and reliable, we think that it can eventually replace DSA.
三维计算机断层血管造影(CTA)是一种最近开发的成像方式。我们证明了这种非侵入性方法在我院收治的蛛网膜下腔出血患者 Willis 环动脉瘤检测中替代数字减影血管造影(DSA)的价值。
对 120 例患者进行螺旋扫描,扫描时床速为每秒 1 毫米,准直为 1 毫米,螺距为 1:1。轴向源图像在 Advantage Windows 控制台工作站(通用电气,威斯康星州密尔沃基)上传输,并使用最大强度投影重建获得 CTA。所有患者均接受了 Willis 环的 DSA 检查(80 例术前检查,40 例术后检查)。
107 例患者共检测出 129 个动脉瘤。三维 CTA 在 13 例患者中未发现异常。92 例患者有 1 个动脉瘤,10 例患者有 2 个,3 例患者有 3 个,2 例患者有 4 个。所有结果均经 DSA 证实。在 2 例中,CTA 检测到大脑中动脉的动脉瘤,但 DSA 未检测到。使用血管造影视图时,动脉瘤总是被大脑中动脉的一个分支遮挡。
三维 CTA 的敏感性与 DSA 相当,其特异性为 100%。由于 CTA 简单、快速、无创且可靠,我们认为它最终可以取代 DSA。