Mapping of pump efficiency on the pressure-flow curve of a centrifugal blood pump.

作者信息

Takami Y, Nakazawa T, Makinouchi K, Glueck J, Benkowski R, Nosé Y

机构信息

Department of Surgery, Baylor College of Medicine, Houston, Texas 77030, USA.

出版信息

Artif Organs. 1997 Aug;21(8):953-7. doi: 10.1111/j.1525-1594.1997.tb00256.x.

Abstract

Because pump efficiency is closely related to heat generation and blood trauma in a centrifugal blood pump, it is quite important to study pump efficiencies in a variety of conditions. In the present study, pump efficiencies were mapped on the pressure head-flow rate curves of 4 different pumps; BioMedicus BioPump (BP-80), Nikkiso (NK), Gyro C1E3, and Gyro PI601 (diameter of the impeller, NK: 50 mm, C1Ee3: 65 mm, and PI601: 50 mm). The mapping of pump efficiency revealed the following findings. First, the cone type (BP-80) has less pump efficiency than the impeller type (NK and C1E3); second, the miniaturization of the C1E3 to the PI601 has resulted in an increase in pump efficiency; and third, the diameter of the impeller may contribute to the pump efficiency of an im peller type pump. The mapping of the pump efficiency, as demonstrated in this study, is useful for the analysis of hydraulic pump performance in a wide range of clinically applied conditions.

摘要

相似文献

1
Mapping of pump efficiency on the pressure-flow curve of a centrifugal blood pump.
Artif Organs. 1997 Aug;21(8):953-7. doi: 10.1111/j.1525-1594.1997.tb00256.x.
2
Feasibility of a tiny Gyro centrifugal pump as an implantable ventricular assist device.
Artif Organs. 1999 Aug;23(8):774-9. doi: 10.1046/j.1525-1594.1999.06421.x.
3
Pump power loss and heat generation in a pivot bearing-supported Gyro centrifugal pump (C1E3).
Artif Organs. 1996 Jul;20(7):794-7. doi: 10.1111/j.1525-1594.1996.tb04542.x.
5
The hemolysis test of the Gyro C1E3 pump in pulsatile mode.
Artif Organs. 1997 Jul;21(7):675-9. doi: 10.1111/j.1525-1594.1997.tb03721.x.
6
Long-term ex vivo bovine experiments with the Gyro C1E3 centrifugal blood pump.
ASAIO J. 2003 Jan-Feb;49(1):112-6. doi: 10.1097/00002480-200301000-00018.
7
Comparison of the Gyro C1E3 and BioMedicus centrifugal pump performances during cardiopulmonary bypass.
Artif Organs. 1997 Jul;21(7):782-5. doi: 10.1111/j.1525-1594.1997.tb03742.x.
9
Effect of surface roughness on hemolysis in a pivot bearing supported Gyro centrifugal pump (C1E3).
Artif Organs. 1996 Nov;20(11):1155-61. doi: 10.1111/j.1525-1594.1996.tb00655.x.

引用本文的文献

1
Development of Inspired Therapeutics Pediatric VAD: Benchtop Evaluation of Impeller Performance and Torques for MagLev Motor Design.
Cardiovasc Eng Technol. 2022 Apr;13(2):307-317. doi: 10.1007/s13239-021-00578-z. Epub 2021 Sep 13.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验