Pelvic floor electrical stimulation in the treatment of stress incontinence: an investigational study and a placebo controlled double-blind trial.

作者信息

Yamanishi T, Yasuda K, Sakakibara R, Hattori T, Ito H, Murakami S

机构信息

Department of Urology, Chiba University School of Medicine, Japan.

出版信息

J Urol. 1997 Dec;158(6):2127-31. doi: 10.1016/s0022-5347(01)68176-x.

Abstract

PURPOSE

We designed an investigational study and a placebo controlled, double-blind study to evaluate the usefulness of electrical pelvic stimulation in stress incontinence.

MATERIALS AND METHODS

We studied 44 patients with stress incontinence (six men and 38 women, age 63 +/- 13), including 9 patients in the investigational study and 35 in the double-blind study. We used 50 Hz. square waves of 1 ms. pulse duration for stimulation. A vaginal electrode was used in women and an anal electrode in men. Urethral pressure profile before, during and after 15-minute stimulation was measured in the investigational study. In the double-blind trial an active device and a dummy device were used, and efficacy was judged from patient impressions, records in frequency/volume chart, results of 1-hour pad test and urodynamic parameters after 4-week treatment.

RESULTS

In the investigational study maximum urethral closure pressure (mean plus or minus standard deviation) before, during and after stimulation was 44.4 +/- 17.5, 64.5 +/- 28.8 and 46.8 +/- 25.6 cm. water, respectively. This parameter significantly increased (p = 0.0275) during stimulation. In the double-blind trial patient impressions were good in 60% of the active device group and 8% of the dummy device group (p = 0.0051). For the pad test significant improvement was noted in the active device group (p = 0.0100). Cure rate was 45% in the active device group and 7.7% in the dummy device group. There were significantly more cured or improved patients for frequency of leakage (p = 0.0196) and pad test (p = 0.0100).

CONCLUSIONS

Electrical stimulation is effective for the treatment of stress incontinence.

摘要

目的

我们设计了一项研究性研究以及一项安慰剂对照双盲研究,以评估电刺激盆腔对压力性尿失禁的治疗效果。

材料与方法

我们研究了44例压力性尿失禁患者(6名男性和38名女性,年龄63±13岁),其中9例参与研究性研究,35例参与双盲研究。我们采用50Hz、脉宽1ms的方波进行刺激。女性使用阴道电极,男性使用肛门电极。在研究性研究中,测量了刺激前、刺激15分钟期间及刺激后的尿道压力曲线。在双盲试验中,使用了有源装置和模拟装置,根据患者的主观感受、频率/尿量图表记录、1小时护垫试验结果以及4周治疗后的尿动力学参数来判断疗效。

结果

在研究性研究中,刺激前、刺激期间及刺激后的最大尿道闭合压(均值±标准差)分别为44.4±17.5、64.5±28.8和46.8±25.6cm水柱。该参数在刺激期间显著增加(p = 0.0275)。在双盲试验中,有源装置组60%的患者主观感受良好,模拟装置组为8%(p = 0.0051)。对于护垫试验,有源装置组有显著改善(p = 0.0100)。有源装置组的治愈率为45%,模拟装置组为7.7%。在漏尿频率(p = 0.0196)和护垫试验(p = 0.0100)方面,治愈或改善的患者明显更多。

结论

电刺激对压力性尿失禁的治疗有效。