Suppr超能文献

Hygicult-tpc在屠宰场卫生控制中的应用。

Use of Hygicult-tpc in slaughterhouse hygiene control.

作者信息

Rahkio T M, Korkeala H J

机构信息

Department of Food and Environmental Hygiene, University of Helsinki, Finland.

出版信息

Acta Vet Scand. 1997;38(4):331-8. doi: 10.1186/BF03548479.

Abstract

Efficacy of Hygicult-tpc contact agar to control hygiene of slaughter equipment before work was studied in 3 slaughterhouses. Brushes from pork lines had higher bacterial counts (77 +/- 114 cfu on Hygicult slide) than other pieces of equipment in pork (55 +/- 101) and beef (42 +/- 110) lines. Low hygienic levels were found also in aprons, knives and conveyor belts. In general, equipment hygiene varied among the slaughterhouses studied (17 +/- 70, 45 +/- 128, 111 +/- 140) and in the comparisons of certain special equipment. Hygienic levels of the equipment were classified into 3 subclasses according to Hygicult counts. Sterilizers and saws had the lowest counts; aprons, and polishing and prescalding brushes had moderate counts. Highest counts were detected in rubber backscraping brushes and steel brushes used to clean pork carcasses and in conveyor belts. Such equipment is difficult to clean, and the bacterial count of 120 on a Hygicult slide is therefore recommended as the acceptable level after cleaning. The level of 50 on a Hygicult slide is recommended as the acceptable level for equipment, which is easy to clean. The limits recommended are based on the distribution of the Hygicult counts obtained. Hygicult-tpc is suitable for slaughterhouse hygiene control with an incubation for 72 h at 25 degrees C. The flexible handle enables sampling of surfaces that are hard to access with unflexible slides and agars.

摘要

在3家屠宰场研究了Hygicult-tpc接触琼脂在工作前控制屠宰设备卫生的效果。猪肉生产线的刷子细菌计数(在Hygicult载玻片上为77±114 cfu)高于猪肉(55±101)和牛肉(42±110)生产线的其他设备。围裙、刀具和传送带的卫生水平也较低。总体而言,在所研究的屠宰场之间(17±70、45±128、111±140)以及某些特殊设备的比较中,设备卫生情况各不相同。根据Hygicult计数,设备的卫生水平分为3个亚类。消毒器和锯的计数最低;围裙以及抛光和预烫刷的计数中等。在用于清洁猪胴体的橡胶刮背刷和钢丝刷以及传送带中检测到的计数最高。此类设备难以清洁,因此建议清洁后Hygicult载玻片上的细菌计数为120作为可接受水平。对于易于清洁的设备,建议Hygicult载玻片上的水平为50作为可接受水平。推荐的限值基于所获得的Hygicult计数分布。Hygicult-tpc适用于屠宰场卫生控制,在25℃下培养72小时。其灵活的手柄使难以用不灵活的载玻片和琼脂接触的表面采样成为可能。

相似文献

本文引用的文献

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验