Suppr超能文献

评估一款商用加速度计(Tritrac-R3 D)在步行过程中测量能量消耗的情况。

Evaluation of a commercial accelerometer (Tritrac-R3 D) to measure energy expenditure during ambulation.

作者信息

Sherman W M, Morris D M, Kirby T E, Petosa R A, Smith B A, Frid D J, Leenders N

机构信息

School of Physical Activity and Educational Services, College of Education, The Ohio State University, Columbus 43210, USA.

出版信息

Int J Sports Med. 1998 Jan;19(1):43-7. doi: 10.1055/s-2007-971878.

Abstract

This study evaluated the ability of a commercially available accelerometer (Tritrac-R3 D) to measure energy expenditure in 16 subjects at rest (pre- and post-exercise) and during three different intensities of steady-state exercise (40-70% of peak oxygen consumption [VO2peak]) while ambulating on a treadmill (no grade). Oxygen consumption and the respiratory exchange ratio from indirect calorimetry and the vector magnitude of triaxial accelerations were used to estimate energy expenditure using the manufacturers' equations. There was a significant relationship between indirect calorimetry-derived energy expenditure and the energy expenditure derived from the accelerometer (r=0.96). Using analysis of variance, there was no difference in the energy expenditure derived by the two methods at rest before exercise and during the three different intensities of ambulatory exercise. There was a significant difference between energy expenditure derived via indirect calorimetry and with the accelerometer during rest after exercise, probably due to the failure of the accelerometer to accurately estimate the energy expenditure associated with the progressive decline in post-exercise oxygen consumption. Thus, this commercially available accelerometer appears to provide statistically acceptable estimates of energy expenditure at rest and during zero-grade treadmill ambulation up to about 70% VO2peak. This may indicate its acceptable utility for large-scale population studies of physical activity involving this mode of movement. The failure of the accelerometer to accurately estimate energy expenditure during recovery from exercise may contribute to an underestimation of energy expenditure in some physically active individuals.

摘要

本研究评估了一款市售加速度计(Tritrac-R3 D)在16名受试者静息状态(运动前和运动后)以及三种不同强度稳态运动(峰值耗氧量[VO2peak]的40%-70%)期间在跑步机(无坡度)上行走时测量能量消耗的能力。利用间接测热法测得的耗氧量和呼吸交换率以及三轴加速度的矢量大小,通过制造商的公式来估算能量消耗。间接测热法得出的能量消耗与加速度计得出的能量消耗之间存在显著相关性(r = 0.96)。通过方差分析,在运动前静息状态以及三种不同强度的行走运动期间,两种方法得出的能量消耗没有差异。运动后静息状态下,间接测热法得出的能量消耗与加速度计得出的能量消耗之间存在显著差异,这可能是由于加速度计未能准确估算与运动后耗氧量逐渐下降相关的能量消耗。因此,这款市售加速度计似乎能在静息状态以及坡度为零的跑步机行走运动期间(VO2peak高达约70%)提供统计学上可接受的能量消耗估算值。这可能表明其在涉及这种运动模式的大规模身体活动人群研究中具有可接受的实用性。加速度计在运动恢复期间未能准确估算能量消耗,可能会导致一些身体活跃个体的能量消耗被低估。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验