Flemmig T F, Petersilka G J, Mehl A, Rüdiger S, Hickel R, Klaiber B
Department of Periodontology, Julius Maximilian University Würzburg, Germany.
Clin Oral Investig. 1997 Jun;1(2):55-60. doi: 10.1007/s007840050011.
This study assessed defect depth and volume resulting from root instrumentation using a KaVo Sonic-flex Lux 2000 L sonic scaler with a slim scaling tip (Perio-Tip no. 8) in vitro. Combinations of the following working parameters were analyzed: lateral forces of 0.5 N, 1 N, and 2 N; tip angulations of 0 degree, 45 degrees, and 90 degrees; and instrumentation time of 10 s, 20 s, 40 s, and 80 s. Defects were quantified using a three-dimensional optical laser scanner. Instrumentation time had an almost linear impact on defect depth and volume. Although lateral force (beta-weight 0.55 +/- 0.062) had a greater influence on defect volume than tip angulation (beta-weight 0.29 +/- 0.062), their effects on defect depth were similar (beta-weight 0.43 +/- 0.052 and 0.50 +/- 0.052, respectively). The combination of force and angulation showed synergistic effects resulting in a wide range of defect depths (21.9 +/- 0.96 microns to 174 +/- 28.8 microns, at 40 s) and volumes (0.056 +/- 0.019 mm3 to 0.68 +/- 0.10 mm3 at 40 s). Severe root damage (> 50 microns/40 s) did not occur at any combination of 0.5 N lateral force and/or 0 degree tip angulation. By adjusting lateral force and tip angulation, the efficacy of the assessed sonic scaler may be adapted to various clinical needs.
本研究在体外使用配备纤细洁治头(牙周洁治头8号)的卡瓦Sonic-flex Lux 2000 L超声洁牙机评估根管预备造成的缺损深度和体积。分析了以下工作参数的组合:0.5 N、1 N和2 N的侧向力;0度、45度和90度的洁治头角度;以及10秒、20秒、40秒和80秒的操作时间。使用三维光学激光扫描仪对缺损进行量化。操作时间对缺损深度和体积几乎有线性影响。尽管侧向力(β权重0.55±0.062)对缺损体积的影响大于洁治头角度(β权重0.29±0.062),但它们对缺损深度的影响相似(分别为β权重0.43±0.052和0.50±0.052)。力和角度的组合显示出协同效应,导致在40秒时出现广泛的缺损深度(21.9±0.96微米至174±28.8微米)和体积(0.056±0.019立方毫米至0.68±0.10立方毫米)。在0.5 N侧向力和/或0度洁治头角度的任何组合下,均未发生严重的牙根损伤(>50微米/40秒)。通过调整侧向力和洁治头角度,所评估的超声洁牙机的功效可适应各种临床需求。