Kaufmann H, Lang R, Rieben A, Varonier H S
Helv Paediatr Acta. 1976 Aug;31(2):131-40.
Peak expiratory flow rate (PEFR) was measured by means of a Wright peak flow meter on a sample of 2865 boys and 2712 girls selected at random in the Canton of Geneva, Switzerland (resident population of Swiss children and adolescents aged 4-19 1/2 in 1972). Technique of measurements and statistical analysis are described with an aim at standardization. Expected percentiles of PEFR (50, 25, 10 and 2.5) versus standing height are presented in tabular form for boys and girls separately. Nomograms are given allowing graphical determination of expected PEFR percentiles in either sex for any given standing height.
采用赖特峰流速仪对瑞士日内瓦州随机抽取的2865名男孩和2712名女孩进行了呼气峰值流速(PEFR)测量(样本为1972年瑞士4至19.5岁儿童及青少年的常住人口)。描述了测量技术和统计分析方法,目的是实现标准化。分别以表格形式列出了男孩和女孩PEFR的预期百分位数(50、25、10和2.5)与身高的关系。给出了列线图,可通过图形确定任何给定身高的男女预期PEFR百分位数。