Quantitative anatomy of the occiput and the biomechanics of occipital screw fixation.

作者信息

Roberts D A, Doherty B J, Heggeness M H

机构信息

Baylor College of Medicine Institute for Spinal Disorders, Houston, Texas, USA.

出版信息

Spine (Phila Pa 1976). 1998 May 15;23(10):1100-7; discussion 1107-8. doi: 10.1097/00007632-199805150-00005.

Abstract

STUDY DESIGN

The surgically relevant osseous anatomy of the human anatomy was carefully studied and described. The stability of cortical and cancellous screws placed in anatomic sites commonly used for internal fixation of the occiput was tested.

OBJECTIVES

To define the bony anatomy of the occiput in quantitative terms and to measure the ability of cortical and cancellous screws inserted at sites commonly used for internal fixation.

SUMMARY OF BACKGROUND DATA

To the authors' knowledge, no previous studies described the gross anatomy of the occiput in specific relation to the internal venous structures in the cranium and to the biomechanical strength of screw fixation in different areas of the occiput.

METHODS

Thirty-seven human occiputs were carefully measured using calipers. Thin sections from six such specimens were analyzed with specific attention to cortical thicknesses. Stability of screws placed in various locations in the occiput were tested in axial pullout.

RESULTS

The thickness of the occiput varied from extremely thin to a 0.1-mm thickness in the region of the cerebellar fossa and increased to a maximum of 8.3 mm at the level of the superior nuchal line and at the transverse sulcus. Results of pullout testing showed that the cancellous screws were as strong as the cortical screws in this area. In areas of the occiput thicker than 7 mm, unicortical fixation was as strong as bicortical fixation.

CONCLUSION

There is a wide variation in thickness of the bone of the occiput. The strength of screw fixation was proportional to the bone's thickness.

摘要

研究设计

对人体解剖学中与手术相关的骨性解剖结构进行了仔细研究和描述。测试了置于枕骨内固定常用解剖部位的皮质骨螺钉和松质骨螺钉的稳定性。

目的

定量定义枕骨的骨性解剖结构,并测量在常用内固定部位插入的皮质骨螺钉和松质骨螺钉的性能。

背景资料总结

据作者所知,此前尚无研究描述枕骨的大体解剖结构与颅骨内静脉结构的具体关系,以及枕骨不同区域螺钉固定的生物力学强度。

方法

用卡尺对37个成人枕骨进行仔细测量。对其中6个标本的薄片进行分析,特别关注皮质厚度。在轴向拔出试验中测试置于枕骨不同位置的螺钉的稳定性。

结果

枕骨厚度变化很大,小脑窝区域极薄至0.1毫米,在上项线和横沟水平增至最大8.3毫米。拔出试验结果表明,该区域松质骨螺钉与皮质骨螺钉强度相当。在枕骨厚度超过7毫米的区域,单皮质固定与双皮质固定强度相同。

结论

枕骨骨质厚度差异很大。螺钉固定强度与骨质厚度成正比。