• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Validity of body composition assessment methods for older men with cardiac disease.

作者信息

Young H, Porcari J, Terry L, Brice G

机构信息

La Crosse Exercise and Health Program, University of Wisconsin--La Crosse, 54601, USA.

出版信息

J Cardiopulm Rehabil. 1998 May-Jun;18(3):221-7. doi: 10.1097/00008483-199805000-00006.

DOI:10.1097/00008483-199805000-00006
PMID:9632324
Abstract

PURPOSE

This study was designed to determine which of several body composition assessment methods was most accurate for patients with cardiac disease for the purpose of outcome measurement.

METHODS

Six body composition assessment methods were administered to each of 24 men with cardiac disease. Methods included circumference measurement, skinfold measurement, near-infrared interactance via the Futrex-5000, bioelectrical impedance via the BioAnalogics ElectroLipoGraph and Tanita TBF-150, and hydrostatic weighing, the criterion measure.

RESULTS

A repeated measures analysis of variance indicated no significant (P > .05) difference between circumference and skinfold measurements compared to hydrostatic weighing. Near-infrared interactance presented the best standard error of estimates (3.5%) and the best correlation (r = .84) with hydrostatic weighing; however, the constant error was 3.76%. Bioelectrical impedance measured by the ElectroLipoGraph and TBF-150 instruments significantly underestimated percent body fat by 8.81% and 4.8%, respectively.

CONCLUSIONS

In this study of middle-aged to older men with cardiac disease, the best method for determining body fat was circumferences. This technique was accurate, easy to administer, inexpensive, and had a lower error potential than the other techniques. Skinfold measurements were also closely related to hydrostatic weighing, but should be performed only by experienced practitioners because there is a greater potential for tester error in certain patients. In the future, near-infrared interactance measurements may be a viable technique for body composition assessment in patients with cardiac disease. However, algorithms specific to the population of patients with cardiac disease being tested must be developed before this technique can be routinely recommended for body composition assessment. Bioelectrical impedance assessment by either method is not recommended for patients with cardiac disease, as it consistently underestimated percent body fat when compared to hydrostatic weighing in this population.

摘要

相似文献

1
Validity of body composition assessment methods for older men with cardiac disease.
J Cardiopulm Rehabil. 1998 May-Jun;18(3):221-7. doi: 10.1097/00008483-199805000-00006.
2
Comparison of three methods for the determination of body fat in patients on long-term hemodialysis therapy.三种测定长期血液透析治疗患者体脂方法的比较。
J Am Diet Assoc. 2003 Feb;103(2):195-9. doi: 10.1053/jada.2003.50024.
3
An evaluation of a bioelectrical impedance analyser for the estimation of body fat content.用于评估体脂含量的生物电阻抗分析仪的评价
Br J Sports Med. 1993 Mar;27(1):63-6. doi: 10.1136/bjsm.27.1.63.
4
Comparison of bioelectric impedance and near-infrared interactance for body composition assessment in a population of self-perceived overweight adults.生物电阻抗与近红外相互作用法在自我感觉超重的成年人群体中用于身体成分评估的比较
Int J Obes Relat Metab Disord. 1994 Jun;18(6):375-81.
5
Comparing body composition assessment tests in long-term hemodialysis patients.比较长期血液透析患者的身体成分评估测试。
Am J Kidney Dis. 2010 May;55(5):885-96. doi: 10.1053/j.ajkd.2009.12.031. Epub 2010 Mar 25.
6
Bioelectric impedance and hydrostatic weighing with and without head submersion in persons who are morbidly obese.病态肥胖者在头部浸没和未浸没情况下的生物电阻抗和水下称重。
J Am Diet Assoc. 1998 Aug;98(8):869-75. doi: 10.1016/S0002-8223(98)00201-6.
7
Evaluation of near infra-red interactance for assessment of subcutaneous and total body fat.评估近红外相互作用用于皮下脂肪和全身脂肪的评估
Eur J Clin Nutr. 1995 Jan;49(1):57-65.
8
Validity of percent body fat estimations in males.男性体脂百分比估计值的有效性。
Med Sci Sports Exerc. 1994 May;26(5):632-6.
9
Are practical methods of evaluating body fat in African-American women accurate?评估非裔美国女性身体脂肪的实用方法准确吗?
Am J Health Promot. 1999 Mar-Apr;13(4):200-2, ii. doi: 10.4278/0890-1171-13.4.200.
10
Validity of leg-to-leg bioelectrical impedance measurement in males.男性双腿生物电阻抗测量的有效性
J Sports Med Phys Fitness. 2001 Sep;41(3):411-4.

引用本文的文献

1
Comparing body composition assessment tests in long-term hemodialysis patients.比较长期血液透析患者的身体成分评估测试。
Am J Kidney Dis. 2010 May;55(5):885-96. doi: 10.1053/j.ajkd.2009.12.031. Epub 2010 Mar 25.
2
Comparative body fat assessment in elite footballers.精英足球运动员身体脂肪评估的比较
Br J Sports Med. 2003 Jun;37(3):278-9. doi: 10.1136/bjsm.37.3.278.