• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Quantification of mitral regurgitation by the automated cardiac output method: an in vitro and in vivo study.

作者信息

Van Camp G, Carlier S, Cosyns B, Plein D, Menassel M, Josse T, Verdonck P, Segers P, Vandenbossche J L

机构信息

St. Pieter University Hospital, Brussels, Belgium.

出版信息

J Am Soc Echocardiogr. 1998 Jun;11(6):643-51. doi: 10.1016/s0894-7317(98)70041-0.

DOI:10.1016/s0894-7317(98)70041-0
PMID:9657404
Abstract

BACKGROUND

Recently, the automated cardiac output method (ACM) was introduced for the calculation of blood flow at the left ventricular outflow tract (LVOT). This study was performed to examine the possibility of using ACM for flow calculation at the level of the mitral valve and for the quantification of mitral regurgitation (MR) in vitro and in vivo.

METHODS AND RESULTS

In a computer-controlled in vitro model of the human heart, aortic and mitral normal bioprosthetic valves were inserted. ACM and electromagnetic probe flow measurements correlated well at the LVOT and at the mitral level (r2 = 0.79 and 0.77, respectively). For stroke volumes ranging from 30 to 100 ml/beat, there was no statistically significant bias between ACM and electromagnetic flow probe (-1.5 and 1.3 ml for LVOT and mitral level, respectively). Limits of agreement were [-14; +11] ml and [-18; +16] ml, respectively. We evaluated 68 patients in our in vivo study. They were divided into three groups according to the results of "standard" echocardiographic Doppler methods for the semiquantification of MR: echocardiographic color Doppler cartography, intensity of the continuous wave Doppler spectra, and in some patients, pulmonary venous flow, conventional Doppler, and proximal isovelocity surface area quantitative data. Group 1 consisted of 35 patients without MR or a physiologic one; the 17 patients in group 2 had a mild MR (1-2/4) and in group 3, 16 patients with MR 3-4/4 were included. Regurgitant volume (RV) was calculated as the difference between ACM mitral flow and ACM aortic flow, and regurgitant fraction (RF) was defined as the ratio between RV and ACM mitral flow. When mitral flow was measured only from the four-chamber view, we found in group 1, RV = -0.57 (0.67) L/min and RF = -16% (19%); in group 2, RV = -0.31 (1.06) L/min and RF = -8% (19%); and in group 3, RV = 1.53 (0.94) L/min and RF = 23% (13%). RV and RF were statistically higher in group 3 compared with group 2 or group 1 (p < 0.0005), but no significant difference was found between groups 1 and 2. When mitral flow was measured by the mean value of ACM four-chamber and two-chamber views, this resulted in group 1, RV = -0.26 (0.63) L/min and RF = -8% (15%); in group 2, RV = 0.01 (1.04) L/min and RF = -2% (18%); and in group 3, RV = 2.07 (1.21) L/min and RF = 34% (19%). RV and RF were again significantly higher in group 3 (p < 0.0001). There was no significant difference between group 1 and group 2, but in group 1 RF was no longer statistically different from 0%.

CONCLUSIONS

(1) In our in vitro setting, ACM is reliable both at the LVOT and at the mitral valve. (2) In the in vivo situation, some overlapping does exist between the three groups of MR. However, ACM is a very easy, rapid, and objective method to differentiate hemodynamic nonsignificant (<3/4) from significant (> or =3/4) MR. Together with other well-known methods for the quantification of MR, it should facilitate the gradation of MR in the clinical setting. The absence of significant differences between group 1 and group 2 proves that the accuracy of ACM measurements at the mitral valve needs to be ameliorated before ACM can be used as a gold standard for the noninvasive measurement of RV and RF.

摘要

相似文献

1
Quantification of mitral regurgitation by the automated cardiac output method: an in vitro and in vivo study.
J Am Soc Echocardiogr. 1998 Jun;11(6):643-51. doi: 10.1016/s0894-7317(98)70041-0.
2
Quantification of mitral regurgitation by automated cardiac output measurement: experimental and clinical validation.通过自动心输出量测量对二尖瓣反流进行定量:实验与临床验证
J Am Coll Cardiol. 1998 Oct;32(4):1074-82. doi: 10.1016/s0735-1097(98)00329-5.
3
Detection, localization, and quantitation of bioprosthetic mitral valve regurgitation. An in vitro two-dimensional color-Doppler flow-mapping study.生物人工二尖瓣反流的检测、定位及定量:一项体外二维彩色多普勒血流成像研究
Circulation. 1988 Sep;78(3):529-38. doi: 10.1161/01.cir.78.3.529.
4
Automated quantification of aortic regurgitant volume and regurgitant fraction using the digital colour Doppler velocity profile integration method in patients with aortic regurgitation.采用数字彩色多普勒速度剖面积分法对主动脉瓣反流患者的主动脉反流容积和反流分数进行自动定量分析。
Heart. 2002 Nov;88(5):481-4. doi: 10.1136/heart.88.5.481.
5
Vena contracta width as a simple method of assessing mitral valve regurgitation. Comparison with Doppler quantitative methods.以缩流宽度作为评估二尖瓣反流的一种简单方法:与多普勒定量方法的比较
J Heart Valve Dis. 2004 Jul;13(4):608-14.
6
Color Doppler regurgitant jet area for evaluating eccentric mitral regurgitation: an animal study with quantified mitral regurgitation.彩色多普勒反流束面积评估偏心性二尖瓣反流:一项二尖瓣反流定量的动物研究
J Am Coll Cardiol. 1994 Sep;24(3):813-9. doi: 10.1016/0735-1097(94)90033-7.
7
Dynamics of mitral regurgitant flow and orifice area. Physiologic application of the proximal flow convergence method: clinical data and experimental testing.二尖瓣反流血流动力学与瓣口面积。近端血流会聚法的生理学应用:临床数据与实验测试
Circulation. 1994 Jul;90(1):307-22. doi: 10.1161/01.cir.90.1.307.
8
Quantitative assessment of primary mitral regurgitation using left ventricular volumes obtained with new automated three-dimensional transthoracic echocardiographic software: A comparison with 3-Tesla cardiac magnetic resonance.应用新型自动化三维经胸超声心动图软件测量左心室容积对原发性二尖瓣反流的定量评估:与 3.0T 心脏磁共振的比较。
Arch Cardiovasc Dis. 2018 Aug-Sep;111(8-9):507-517. doi: 10.1016/j.acvd.2017.10.008. Epub 2018 Mar 31.
9
Evaluation of mitral regurgitation using a digitally determined color Doppler flow convergence 'centerline' acceleration method. Studies in an animal model with quantified mitral regurgitation.使用数字确定的彩色多普勒血流会聚“中心线”加速度方法评估二尖瓣反流。在具有定量二尖瓣反流的动物模型中的研究。
Circulation. 1994 Jun;89(6):2879-87. doi: 10.1161/01.cir.89.6.2879.
10
[Echocardiography flow quantification for determining the severity of heart valve insufficiency].
Herz. 2002 May;27(3):254-68. doi: 10.1007/s00059-002-2378-3.

引用本文的文献

1
Three dimensional colour Doppler echocardiography for the characterisation and quantification of cardiac flow events.三维彩色多普勒超声心动图用于心脏血流事件的特征描述和定量分析。
Heart. 2000 Nov;84 Suppl 2(Suppl 2):II2-6. doi: 10.1136/heart.84.suppl_2.ii2.