Kreel L
Acta Radiol Diagn (Stockh). 1976 Jul;17(4):405-12. doi: 10.1177/028418517601700403.
Thirteen individuals with varying lengths of exposure to asbestosis were examined by computer tomography with the EMI Scanner. Various pleuroparenchymal abnormalities were found, many not being seen on standard chest films. In some cases, with normal chest radiography, definite pleural involvement could be demonstrated, particularly that in the posterior sulci on the diaphragm and at the mediastinum. Tissue attenuation measurements in regions of parenchymal involvement reached 90 EMI units above normal lung tissue. The normal gravity effect is abolished in cases of parenchymal disease caused by asbestosis. Parenchymal disease was much more obvious on the CT scans than on conventional chest films.
使用EMI扫描仪对13名接触石棉沉着病时长各异的个体进行了计算机断层扫描检查。发现了各种胸膜实质异常,其中许多在标准胸部X光片上未见。在某些病例中,胸部X光片正常,但可显示明确的胸膜受累,尤其是膈肌后沟和纵隔处。实质受累区域的组织衰减测量值比正常肺组织高出90个EMI单位。石棉沉着病引起的实质疾病病例中正常重力效应消失。计算机断层扫描上的实质疾病比传统胸部X光片上更明显。