Suppr超能文献

纤维支气管镜检查引起的通气-灌注改变

Ventilation-perfusion alterations induced by fiberoptic bronchoscopy.

作者信息

Brach B B, Escano G G, Harrell J H, Moser K M

出版信息

Chest. 1976 Mar;69(3):335-7. doi: 10.1378/chest.69.3.335.

Abstract

Pulmonary perfusion (Q) and ventilation (V) scintiphotography was performed in 16 patients undergoing diagnostic fiberoptic bronchoscopic examinations. Regional V/Q did not change in the majority of the patients who developed hypoxemia after bronchoscopic studies. An improvement in V/Q was detectable in the patients with a rise in arterial oxygen pressure (PaO2) after bronchoscopic examination, and this rise was associated in most with the removal of mucous plugs or extensive secretions. The data indicate that the behavior of PaO2 after bronchoscopic study is dependent upon both the extent of lavage and the yield of the procedure in terms of secretions and plugs. The results also indicate that the removal of secretions or plugs can be associated with rapid return of regional V and Q.

摘要

对16例接受诊断性纤维支气管镜检查的患者进行了肺灌注(Q)和通气(V)闪烁摄影。在大多数支气管镜检查后发生低氧血症的患者中,局部V/Q没有变化。在支气管镜检查后动脉血氧分压(PaO2)升高的患者中可检测到V/Q改善,并且这种升高在大多数情况下与粘液栓或大量分泌物的清除有关。数据表明,支气管镜检查后PaO2的变化既取决于灌洗的程度,也取决于该操作在分泌物和栓子清除方面的效果。结果还表明,分泌物或栓子的清除可能与局部V和Q的迅速恢复有关。