Abstract

BACKGROUND

In isolated working guinea pig heart preparations using the conventional technique of cannulating the left atrium via the atrial appendage, the resulting cardiac output is often insufficiently low (15-20 ml/min). This is a problem in ischemia reperfusion studies where small absolute differences can be responsible for large relative changes comparing pre- and postischemic values. In an attempt to increase cardiac output, the left atrium was left intact in isolated working guinea pig hearts. The two techniques were compared for hemodynamic parameters and their similarity to the physiological condition.

METHODS

The left atrium was cannulated either via the orifices of the pulmonary veins or via an incision in the atrial appendage with its subsequent ligation around the cannula (n = 45-46/group). After 20 min of pressure-volume work cardiac output, heart rate and oxygen partial pressures were measured and myocardial oxygen consumption and cardiac efficiency were calculated.

RESULTS

Cardiac output was higher in hearts with intact atrial appendage (64 +/- 2 ml/min) than in hearts with ligated atrial appendage (33 +/- 1 ml/min). Myocardial oxygen consumption (6.1 +/- 0.2 and 8.4 +/- 0.3 micromol/min, resp.) and cardiac efficiency (12.8 +/- 0.6% and 19.9 +/- 0.8%, resp.) were significantly higher in hearts with intact left atrial appendage.

CONCLUSIONS

Isolated working guinea pig hearts with an intact left auricle exhibit higher values for important hemodynamic parameters compared to a preparation technique involving ligation of the left auricle.

摘要

背景

在使用经心耳插管至左心房的传统技术制备的离体豚鼠工作心脏标本中,所得到的心输出量往往不够低(15 - 20毫升/分钟)。这在缺血再灌注研究中是个问题,因为在比较缺血前后的值时,小的绝对差异可能导致大的相对变化。为了增加心输出量,在离体豚鼠工作心脏中保留左心房完整。比较了这两种技术的血流动力学参数及其与生理状况的相似性。

方法

通过肺静脉口或经心耳切口插管至左心房,随后在插管周围结扎(每组n = 45 - 46)。在进行20分钟压力 - 容积工作后,测量心输出量、心率和氧分压,并计算心肌耗氧量和心脏效率。

结果

保留心耳完整的心脏的心输出量(64±2毫升/分钟)高于结扎心耳的心脏(33±1毫升/分钟)。保留左心耳完整的心脏的心肌耗氧量(分别为6.1±0.2和8.4±0.3微摩尔/分钟)和心脏效率(分别为12.8±0.6%和19.9±0.8%)显著更高。

结论

与涉及结扎左心耳的制备技术相比,保留完整左耳的离体豚鼠工作心脏的重要血流动力学参数值更高。