• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

A comparison of two bipolar exercise electrocardiographic leads to lead V5.

作者信息

Froelicher V F, Wolthius R, Keiser N, Stewart A, Fischer J, Longo M R, Triebwasser J H, Lancaster M C

出版信息

Chest. 1976 Nov;70(5):611-6. doi: 10.1378/chest.70.5.611.

DOI:10.1378/chest.70.5.611
PMID:975977
Abstract

ST-segment depression and slope were compared in three lead systems (V5, CC5, and CM5) and in two groups of patients using both visual analysis of electrocardiographic paper and computerized techniques. Bipolar lead CC5 was found to be comparable to lead V5 when visual analysis of electrocardiographic recordings was utilized. Bipolar lead CM5 was found not to be comparable to lead V5 and to be less sensitive if classic criteria for slope were used. The technique of computerized analysis mad measurements of slope and amplitude to a reproducible level not possible with the standard technique. Statistically significant differences were found between the exercise electrocardiographic leads utilizing computerized electrocardiographic analysis . We conclude that computerized techniques of electrocardiographic analysis require new criteria for defining an abnormal repolarization response. The criteria must be specific for different electrocardiographic leads if the repolarization changes in these leads are to have comparable diagnostic significance.

摘要

相似文献

1
A comparison of two bipolar exercise electrocardiographic leads to lead V5.
Chest. 1976 Nov;70(5):611-6. doi: 10.1378/chest.70.5.611.
2
Value of the bipolar lead CM5 in electrocardiography.双极导联CM5在心电图检查中的价值。
Br Heart J. 1986 Oct;56(4):372-6. doi: 10.1136/hrt.56.4.372.
3
Computer analysis of exercise-induced changes in electrocardiographic variables. Comparison of methods and criteria.运动诱发心电图变量变化的计算机分析。方法与标准的比较。
Chest. 1983 Dec;84(6):699-706. doi: 10.1378/chest.84.6.699.
4
[Evaluation of 3 chest leads CM5, CC5, and CL5 and factors which influence the results].[3个胸导联CM5、CC5和CL5的评估以及影响结果的因素]
Zhonghua Xin Xue Guan Bing Za Zhi. 1989 Apr;17(2):103-6, 127-8.
5
Comparison of ST segment changes on standard and Holter electrocardiogram during exercise testing.
Cardiologia. 1992 Dec;37(12):871-5.
6
[Computer analysis of the ECG during physical exercise].[体育锻炼期间心电图的计算机分析]
Kardiologiia. 1984 Mar;24(3):70-5.
7
Value of leads V4R and CM5 in the detection of coronary artery disease during exercise electrocardiographic test.运动心电图测试中V4R导联和CM5导联在冠心病检测中的价值。
Clin Physiol Funct Imaging. 2010 Jul;30(4):308-12. doi: 10.1111/j.1475-097X.2010.00942.x. Epub 2010 May 24.
8
Variations in normal electrocardiographic response to treadmill testing.跑步机测试中正常心电图反应的变异
Am J Cardiol. 1981 May;47(5):1161-7. doi: 10.1016/0002-9149(81)90229-0.
9
Intraoperative myocardial ischemia: localization by continuous 12-lead electrocardiography.术中心肌缺血:通过连续12导联心电图进行定位
Anesthesiology. 1988 Aug;69(2):232-41.
10
Exercise-induced ST-segment depression in inferior leads during treadmill exercise testing and coronary artery disease.运动平板试验中Ⅱ、Ⅲ、aVF 导联 ST 段压低与冠状动脉疾病。
Int J Cardiol. 2010 Dec 3;145(3):e88-91. doi: 10.1016/j.ijcard.2008.12.163. Epub 2009 Jan 26.

引用本文的文献

1
Beat-ID: Towards a computationally low-cost single heartbeat biometric identity check system based on electrocardiogram wave morphology.心跳识别(Beat-ID):迈向基于心电图波形形态的计算成本低的单心跳生物特征身份验证系统。
PLoS One. 2017 Jul 18;12(7):e0180942. doi: 10.1371/journal.pone.0180942. eCollection 2017.
2
Intraoperative automated ST segment analysis: a reliable 'black box'?
Can J Anaesth. 1996 Oct;43(10):1041-51. doi: 10.1007/BF03011907.
3
Evaluation and management of the cardiac patient for office oral surgery.心脏病人接受口腔门诊手术的评估与管理。
Anesth Prog. 1983 May-Jun;30(3):67-71.
4
Simplified electrode array for impedance cardiography.
Med Biol Eng Comput. 1985 Jan;23(1):1-7. doi: 10.1007/BF02444019.
5
Value of the bipolar lead CM5 in electrocardiography.双极导联CM5在心电图检查中的价值。
Br Heart J. 1986 Oct;56(4):372-6. doi: 10.1136/hrt.56.4.372.
6
Anaesthesia for abdominal aortic surgery--a review (Part II).腹主动脉手术的麻醉——综述(第二部分)
Can J Anaesth. 1989 Sep;36(5):568-77. doi: 10.1007/BF03005388.
7
Hemodynamic monitoring and care of the patient of high risk for anesthesia.麻醉高危患者的血流动力学监测与护理
Can Med Assoc J. 1979 Oct 6;121(7):922-4, 926-8.
8
Diagnostic value of routine exercise testing in hospital patients with angina pectoris.常规运动试验对医院心绞痛患者的诊断价值。
Br Med J. 1979 Aug 4;2(6185):295-7. doi: 10.1136/bmj.2.6185.295.