Monitoring of 140 patients after hip-replacement arthroplasty using both impedance plethysmography and 125I fibrinogen scanning of the lower extremities showed that half had no evidence of thrombosis, one-quarter had moderate or extensive thrombosis, and one-quarter had abnormal scans only. In the patients with only abnormal scans the process appeared to resolve spontaneously. The findings by impedance plethysmography therefore appeared to differentiate non-invasively between thromboses that would and would not resolve, and it is suggested that for some patients a monitoring regimen may be preferable to routine prophylaxis.
对140例髋关节置换术后患者同时采用阻抗体积描记法和下肢¹²⁵I纤维蛋白原扫描进行监测,结果显示,一半患者无血栓形成迹象,四分之一患者有中度或广泛血栓形成,四分之一患者仅扫描结果异常。在仅扫描结果异常的患者中,病情似乎会自行缓解。因此,阻抗体积描记法的结果似乎能无创地区分可自行缓解和不可自行缓解的血栓形成,有人建议,对于某些患者,监测方案可能比常规预防措施更可取。