Experimental determination of dosimetry functions of Ir-192 sources.

作者信息

Anctil J C, Clark B G, Arsenault C J

机构信息

Medical Physics Unit, McGill University, Montréal, Québec, Canada.

出版信息

Med Phys. 1998 Dec;25(12):2279-87. doi: 10.1118/1.598457.

Abstract

Experimental data related to the dosimetric characteristics of Ir-192 brachytherapy sources are limited. The aim of this work was to obtain the dosimetry functions required by the American Association of Physicists in Medicine Task Group 43 for both a low and a high dose-rate iridium-192 brachytherapy source through dose measurements in a water-equivalent phantom. Dose measurements have been performed using lithium fluoride thermoluminescent detectors positioned in a polystyrene phantom at distances from the source that vary from 1 to 10 cm, with 1 cm intervals, and at angles that vary from 0 degree to 170 degrees with 10 degrees intervals. The anisotropy functions, radial dose functions, and dose rate constants were determined for both brachytherapy sources. The precision of results obtained on those relatively fine intervals of angles and distances provides clinics with the possibility to use and interpolate the complete data sets for treatment planning.