Suppr超能文献

评估一种用于检测人类临床样本中分枝杆菌的非放射性系统(BACTEC 9000 MB)。

Evaluation of a nonradiometric system (BACTEC 9000 MB) for detection of mycobacteria in human clinical samples.

作者信息

Zanetti S, Ardito F, Sechi L, Sanguinetti M, Molicotti P, Delogu G, Pinna M P, Nacci A, Fadda G

机构信息

Institute of Microbiology and Virology, University of Sassari, Italy.

出版信息

J Clin Microbiol. 1997 Aug;35(8):2072-5. doi: 10.1128/jcm.35.8.2072-2075.1997.

Abstract

This study was carried out to evaluate the rate of recovery and time required for detection of mycobacteria from pulmonary and extrapulmonary human clinical samples, by using a fluorescence-quenching-based oxygen sensor (BACTEC 9000 MB; Becton Dickinson Microbiology Systems, Sparks, Md.). The results were compared with those obtained by microscopy, conventional culture in Lowenstein-Jensen (LJ) medium, and a BACTEC radiometric system (BACTEC 460 TB; Becton Dickinson). Of the 779 clinical samples processed, 364 from pulmonary sites and 415 from extrapulmonary sites, 62 (7.9%) were positive for mycobacterial isolates; of the positive samples, 59 (95.1%) were detected with the fluorescent BACTEC 9000 MB system, 57 (91.9%) were detected with the radiometric system (BACTEC 460 TB), and 43 (69.3%) were detected with LJ conventional culture. The mean times to detection of all mycobacteria with BACTEC 9000 MB and BACTEC 460 TB were similar (10.3 and 10.0 days, respectively). The results obtained indicate that the nonradiometric BACTEC (BACTEC 9000 MB) system is as efficient as Bactec 460 TB and significantly more efficient than LJ for the rapid recovery of mycobacteria from both pulmonary and extrapulmonary clinical specimens. Though the BACTEC 9000 MB system is recommended for respiratory specimens, we demonstrated that it can be successfully used also for recovery of mycobacteria from clinical specimens from various extrapulmonary sites.

摘要

本研究旨在通过使用基于荧光猝灭的氧传感器(BACTEC 9000 MB;Becton Dickinson微生物系统公司,马里兰州斯帕克斯),评估从人类肺部和肺外临床样本中检测分枝杆菌的回收率和所需时间。将结果与通过显微镜检查、在罗-琴(LJ)培养基中进行常规培养以及BACTEC放射测量系统(BACTEC 460 TB;Becton Dickinson)获得的结果进行比较。在处理的779份临床样本中,364份来自肺部,415份来自肺外部位,62份(7.9%)分枝杆菌分离株呈阳性;在阳性样本中,59份(95.1%)通过荧光BACTEC 9000 MB系统检测到,57份(91.9%)通过放射测量系统(BACTEC 460 TB)检测到,43份(69.3%)通过LJ常规培养检测到。使用BACTEC 9000 MB和BACTEC 460 TB检测所有分枝杆菌的平均时间相似(分别为10.3天和10.0天)。获得的结果表明,非放射测量的BACTEC(BACTEC 9000 MB)系统与Bactec 460 TB一样有效,并且在从肺部和肺外临床标本中快速分离分枝杆菌方面明显比LJ更有效。尽管推荐将BACTEC 9000 MB系统用于呼吸道标本,但我们证明它也可以成功用于从各种肺外部位的临床标本中分离分枝杆菌。

相似文献

引用本文的文献

本文引用的文献

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验