Salgarello T, Colotto A, Falsini B, Buzzonetti L, Cesari L, Iarossi G, Scullica L
Institute of Ophthalmology, Catholic University, Rome, Italy.
Invest Ophthalmol Vis Sci. 1999 Aug;40(9):1989-97.
To evaluate the correlation of pattern electroretinogram (PERG), an index of inner retinal function, with confocal scanning laser (CSLO) optic disc structural parameters in ocular hypertension (OHT).
Thirty-four patients with OHT, normal white-on-white (Humphrey 30-2) perimetry, and normal clinical optic discs were examined with PERG and CSLO disc analysis. Two groups of normal subjects (n = 38 and 18, for PERG and CSLO, respectively) and a group of 12 patients with early open-angle glaucoma (EOAG) were also tested. Pattern electroretinogram amplitudes were measured in response to sinusoidal gratings of variable spatial frequency (0.58-5.8 cycles/degree), modulated in counter-phase at 7.5 Hz. Morphometric optic disc parameters were obtained by the Heidelberg Retina Tomograph (HRT), either globally or from predefined disc sectors. In addition to standard parameters, the cup shape measure, an index of depth variation and steepness of the cup walls, was determined.
In individual OHT patients, PERG amplitudes at 2.6 cycles/degree were negatively correlated with cup shape measures (r = -0.43, P < 0.01) obtained from analysis of the inferotemporal (IT) sector. No significant correlations were found for the other parameters. On average, the cup shape measures derived from IT sector or global analysis were significantly (P < 0.01) worse, and closer to the measures of EOAG patients, in OHT patients with abnormal PERG compared with those with normal PERGs. The cup shape measure displayed a low sensitivity (20%) and a high specificity (100%) in predicting PERG abnormalities in individual OHT patients.
The results indicate that in OHT there is a significant although weak correlation between PERG amplitude and the shape of the optic disc cup, suggesting a parallel involvement of both function and morphology. Combined PERG and optic disc cup structural analysis is of potential diagnostic value to detect early damage to optic nerve head in individual OHT patients.
评估作为视网膜内层功能指标的图形视网膜电图(PERG)与高眼压症(OHT)患者共焦扫描激光(CSLO)视盘结构参数之间的相关性。
对34例高眼压症患者进行了PERG和CSLO视盘分析,这些患者 Humphrey 30-2 白色视野检查正常,临床视盘正常。还测试了两组正常受试者(分别为38例和18例,用于PERG和CSLO)以及一组12例早期开角型青光眼(EOAG)患者。测量了对可变空间频率(0.58 - 5.8周期/度)的正弦光栅以7.5 Hz反相调制的图形视网膜电图振幅。通过海德堡视网膜断层扫描仪(HRT)获得视盘形态测量参数,可进行整体测量或从预定义的视盘区域测量。除标准参数外,还确定了杯状形态测量指标,即杯壁深度变化和陡峭程度的指标。
在个体高眼压症患者中,2.6周期/度时的PERG振幅与从颞下(IT)区域分析获得的杯状形态测量指标呈负相关(r = -0.43,P < 0.01)。其他参数未发现显著相关性。平均而言,与PERG正常的高眼压症患者相比,PERG异常的高眼压症患者从IT区域或整体分析得出的杯状形态测量指标显著更差(P < 0.01),且更接近早期开角型青光眼患者的指标。杯状形态测量指标在预测个体高眼压症患者PERG异常方面显示出低敏感性(20%)和高特异性(100%)。
结果表明,在高眼压症中,PERG振幅与视盘杯状形态之间存在显著但较弱的相关性,提示功能和形态可能同时受累。PERG与视盘杯状结构分析相结合对检测个体高眼压症患者早期视神经乳头损伤具有潜在诊断价值。