Suppr超能文献

电解氧化水对大肠杆菌O157:H7、肠炎沙门氏菌和单核细胞增生李斯特菌的灭活效果。

Efficacy of electrolyzed oxidizing water for inactivating Escherichia coli O157:H7, Salmonella enteritidis, and Listeria monocytogenes.

作者信息

Venkitanarayanan K S, Ezeike G O, Hung Y C, Doyle M P

机构信息

Department of Animal Science, University of Connecticut, Storrs, Connecticut 06269, USA.

出版信息

Appl Environ Microbiol. 1999 Sep;65(9):4276-9. doi: 10.1128/AEM.65.9.4276-4279.1999.

Abstract

The efficacy of electrolyzed oxidizing water for inactivating Escherichia coli O157:H7, Salmonella enteritidis, and Listeria monocytogenes was evaluated. A five-strain mixture of E. coli O157:H7, S. enteritidis, or L. monocytogenes of approximately 10(8) CFU/ml was inoculated in 9 ml of electrolyzed oxidizing water (treatment) or 9 ml of sterile, deionized water (control) and incubated at 4 or 23 degrees C for 0, 5, 10, and 15 min; at 35 degrees C for 0, 2, 4, and 6 min; or at 45 degrees C for 0, 1, 3, and 5 min. The surviving population of each pathogen at each sampling time was determined on tryptic soy agar. At 4 or 23 degrees C, an exposure time of 5 min reduced the populations of all three pathogens in the treatment samples by approximately 7 log CFU/ml, with complete inactivation by 10 min of exposure. A reduction of >/=7 log CFU/ml in the levels of the three pathogens occurred in the treatment samples incubated for 1 min at 45 degrees C or for 2 min at 35 degrees C. The bacterial counts of all three pathogens in control samples remained the same throughout the incubation at all four temperatures. Results indicate that electrolyzed oxidizing water may be a useful disinfectant, but appropriate applications need to be validated.

摘要

评估了电解氧化水对大肠杆菌O157:H7、肠炎沙门氏菌和单核细胞增生李斯特菌的灭活效果。将大约10(8) CFU/ml的大肠杆菌O157:H7、肠炎沙门氏菌或单核细胞增生李斯特菌的五菌株混合物接种于9 ml电解氧化水(处理组)或9 ml无菌去离子水(对照组)中,并在4℃或23℃下孵育0、5、10和15分钟;在35℃下孵育0、2、4和6分钟;或在45℃下孵育0、1、3和5分钟。在胰蛋白胨大豆琼脂上测定每个采样时间点每种病原体的存活菌数。在4℃或23℃下,5分钟的暴露时间使处理组样品中所有三种病原体的菌数减少约7 log CFU/ml,暴露10分钟可完全灭活。在45℃下孵育1分钟或在35℃下孵育2分钟的处理组样品中,三种病原体的水平降低>/=7 log CFU/ml。在所有四个温度下的整个孵育过程中,对照组样品中所有三种病原体的细菌计数保持不变。结果表明,电解氧化水可能是一种有用的消毒剂,但需要验证其适当的应用方法。

相似文献

引用本文的文献

10
Potential of electrolyzed water for disinfection of foot-and-mouth disease virus.电解水对口蹄疫病毒的消毒潜力。
J Vet Med Sci. 2017 Apr 5;79(4):726-729. doi: 10.1292/jvms.16-0614. Epub 2017 Feb 18.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验