Suppr超能文献

对比剂对经颅多普勒评估正常大脑中动脉收缩期峰值流速的影响。

The effect of contrast material on transcranial Doppler evaluation of normal middle cerebral artery peak systolic velocity.

作者信息

Khan H G, Gailloud P, Bude R O, Martin J B, Szopinski K T, Khaw C, Rüfenacht D A, Murphy K J

机构信息

Division of Diagnostic and Interventional Radiology, Geneva University Hospital, Switzerland.

出版信息

AJNR Am J Neuroradiol. 2000 Feb;21(2):386-90.

Abstract

BACKGROUND AND PURPOSE

Several recent studies have shown that sonographic contrast agents may affect transcranial Doppler evaluation of the arterial peak systolic velocity (PSV). Some investigators reported an increase in PSV, and others reported no change in PSV compared with baseline values. This study was conducted to determine the effect of sonographic contrast agent on PSV measured in normal middle cerebral arteries.

METHODS

Continuous spectral Doppler sonography was performed on the right middle cerebral artery of 20 participants with angiographically proven normal intracranial vasculature. Videotaping was performed in each case from the initiation of the administration of contrast medium until the effect of the contrast agent on the PSV subsided. The PSV values were normalized for each participant, were pooled, and were plotted as a function of time.

RESULTS

PSV increased in all participants after the administration of contrast material; the mean maximum increase was 24+/-7.4% (mean +/- standard deviation) (range, 15-36%). The mean duration of PSV increase was 320+/-97 s (range, 165-465 s).

CONCLUSION

The middle cerebral artery PSV increased substantially after the administration of contrast material. This effect needs to be considered if velocity thresholds developed for disease detection without the use of contrast materials are used when contrast agents are administered.

摘要

背景与目的

最近的几项研究表明,超声造影剂可能会影响经颅多普勒对动脉收缩期峰值流速(PSV)的评估。一些研究者报告PSV升高,而另一些研究者报告与基线值相比PSV无变化。本研究旨在确定超声造影剂对正常大脑中动脉PSV测量值的影响。

方法

对20名经血管造影证实颅内血管正常的参与者的右侧大脑中动脉进行连续频谱多普勒超声检查。在每种情况下,从开始注射造影剂直到造影剂对PSV的影响消退,都进行录像。对每个参与者的PSV值进行标准化处理,汇总后绘制为时间的函数。

结果

注射造影剂后,所有参与者的PSV均升高;平均最大增幅为24±7.4%(平均值±标准差)(范围为15 - 36%)。PSV升高的平均持续时间为320±97秒(范围为165 - 465秒)。

结论

注射造影剂后大脑中动脉PSV显著升高。当使用造影剂时,如果采用未使用造影剂时制定的疾病检测速度阈值,则需要考虑这种影响。

相似文献

3
The Effect of the Pressure Exerted on the Maternal Abdominal Wall by the US Probe on Fetal MCA Peak Systolic Velocity.
Ultraschall Med. 2017 Jan;38(1):44-50. doi: 10.1055/s-0035-1553332. Epub 2015 Sep 30.
8
Transcranial Doppler: state of the art.经颅多普勒:最新技术水平
Eur J Radiol. 1998 May;27 Suppl 2:S141-8. doi: 10.1016/s0720-048x(98)00055-2.

本文引用的文献

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验