Suppr超能文献

永久性心内膜起搏。90例患者的分析。

Permanent endocardial pacing. An analysis of 90 patients.

作者信息

Havia T, Arstila M, Wendelin H, Heinonen R

出版信息

Acta Med Scand Suppl. 1976;596:7-11.

PMID:1070229
Abstract

Primary results and follow-up observations in 90 patients with permanent endocardial pacing--covering the period from 1970 to June 1974--are reported. The primary mortality was 3% (3/90), and mortality 4% (4/90). Electrode complications were the most common problem and occurred in 20% implantations. Early or late dislocation of the electrode tip was seen in 12%. With the improved technique is was possible to decrease it significantly through the period. The mean battery life time of Siemens-Elema pacemakers was 26 months. 10% of the failed batteries were replaced urgently. So far the rather high frequency of electrode complications diminishes the advantages of the pacemaker treatment.

摘要

本文报告了90例永久性心内膜起搏患者从1970年至1974年6月期间的主要结果及随访观察情况。主要死亡率为3%(3/90),总死亡率为4%(4/90)。电极并发症是最常见的问题,在20%的植入手术中出现。电极尖端早期或晚期脱位的发生率为12%。随着技术的改进,在此期间有可能显著降低该发生率。西门子 - 伊莱玛起搏器的平均电池使用寿命为26个月。10%的电池失效后进行了紧急更换。迄今为止,电极并发症的较高发生率削弱了起搏器治疗的优势。