Dalmasso F, Pellegrino S, Trapani C, Bellero V
Minerva Med. 1976 Oct 17;67(49):3207-12.
Alpha-1 antitrypsin levels were determined in 27 pleural effusion liquids classified as transudates and exudates in accordance with the clinical and laboratory data, and in their respective blood samples. Absolute values proved insufficient to distinguish transudates from exudates, though they were capable of signifying and replacing the relative protein value. The relation between liquid: serum alpha-1 AT ratio and the liquid: serum proteins ratio was direct and highly significant. Along with the liquid: serum LAD and liquid: serum proteins ratios, the liquid: serum alpha-1 AT ratio enables transudates and exudates to be differentiated with certainty.
根据临床和实验室数据,对27份被分类为漏出液和渗出液的胸腔积液及其各自的血液样本测定了α-1抗胰蛋白酶水平。绝对值不足以区分漏出液和渗出液,尽管它们能够表示并替代相对蛋白值。胸水:血清α-1抗胰蛋白酶比值与胸水:血清蛋白比值之间呈直接且高度显著的关系。与胸水:血清乳酸脱氢酶和胸水:血清蛋白比值一样,胸水:血清α-1抗胰蛋白酶比值能够确切地区分漏出液和渗出液。