Suppr超能文献

Laboratory contamination of blood cultures.

作者信息

Spencer R C, Savage M A

出版信息

J Clin Pathol. 1975 Dec;28(12):980-2. doi: 10.1136/jcp.28.12.980.

Abstract

A prospective study of the use of a laminar flow cabinet, an exhaust-ventilated safety hood, and the open bench for the microbiological examination of blood is described. Blood samples from 1600 patients were subcultured on the open bench, 2700 in a safety hood, and 2607 in a laminar flow cabinet. Use of the laminar flow cabinet produced a significantly greater level of contamination than the other methods, and it is concluded that the exhaust-ventilated safety hood should be used for this procedure.

摘要
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/6a52/475918/d9e0b1d01586/jclinpath00146-0054-a.jpg