A method is described for the determination of anabolic steroids including testosterone, 19-nor-4-androstene-3,17-dione, 4-androstene-3,17-dione and nandrolone in food supplements. Initial clean-up is done by HPLC followed by determination with GC/MS. A 'contaminated' food supplement was analysed and appeared to contain 19-nor-4-androstene-3,17-dione and 4-androstene-3,17-dione. One capsule of this nutritional supplement was ingested by five male volunteers. Urine samples were collected and analysed by GC/MS and GC/MS-MS. Neither the ratio testosterone/epitestosterone, nor the ratio androstenedione/epitestosterone increased significantly. Concentrations above 2 ng/ml for norandrosterone, the major metabolite of nandrolone, were detected until 48-144 h after ingestion of the food supplement.

摘要

描述了一种用于测定食品补充剂中包括睾酮、19-去甲-4-雄烯-3,17-二酮、4-雄烯-3,17-二酮和诺龙在内的合成代谢类固醇的方法。首先通过高效液相色谱法进行净化,然后用气相色谱/质谱法进行测定。对一种“受污染的”食品补充剂进行了分析,结果显示其含有19-去甲-4-雄烯-3,17-二酮和4-雄烯-3,17-二酮。五名男性志愿者服用了一粒这种营养补充剂胶囊。收集尿液样本并通过气相色谱/质谱法和气相色谱/质谱-质谱法进行分析。睾酮/表睾酮的比值以及雄烯二酮/表睾酮的比值均未显著升高。在摄入该食品补充剂后48至144小时内,检测到诺龙的主要代谢产物去甲雄酮的浓度高于2纳克/毫升。