Isometric strength measurement for muscle weakness in cancer patients: reproducibility of isometric muscle strength measurements with a hand-held pull-gauge dynamometer in cancer patients.

作者信息

Knols Ruud H, Stappaerts Karel H, Fransen Jaap, Uebelhart Daniel, Aufdemkampe Geert

机构信息

Department of Rheumatology and Institute of Physical Medicine, U Ost 154, University Hospital of Zurich, Gloriastrasse 25, 8091 Zurich, Switzerland.

出版信息

Support Care Cancer. 2002 Jul;10(5):430-8. doi: 10.1007/s00520-002-0343-6. Epub 2002 Feb 9.

Abstract

Our aim was to determine several indexes of reproducibility for strength measurements with a hand-held pull-gauge dynamometer (MFB50K) in cancer patients. Two independent testers performed repeated measurements of maximal isometric elbow and knee strength. The measurements were gathered in a convenience sample of 40 patients (27 men, age 20-72 years) with various types and stages of cancer. These patients were recruited from the medical oncology clinic of a university hospital. The Pearson product moment correlation coefficient, the intraclass correlation coefficient (ICC), the standard error of measurement (SEM) and its associated 95% confidence interval, the smallest detectable difference (SDD) and the limits of agreement were determined as outcome measures for reproducibility. The results for the Pearson product moment correlation and the ICC were 0.90 for elbow and 0.96 for knee extension strength. The results in terms of the SDDs were 29.4 newton (N) for elbow and 54.8 N for knee strength. The limits of agreement for elbow strength were -21.7 N and 38.5 N (mean 8.4 N). For knee strength the limits of agreement were -49.8 N and 59.8 N (mean 5 N). The Pearson product moment correlation and the ICC suggested good reproducibility. However, the more informative indices of reproducibility, i.e. the SEM and the SDD, showed relatively large measurement error between the testers. Therefore, the current use of the MFB50K for the measurement of muscle strength is not supported in cancer patients.

摘要

我们的目的是确定癌症患者使用手持式拉力计测力计(MFB50K)进行力量测量的几个重复性指标。两名独立测试人员对最大等长肘部和膝部力量进行了重复测量。测量数据来自40名患者(27名男性,年龄20 - 72岁)的便利样本,这些患者患有各种类型和阶段的癌症。这些患者是从一家大学医院的医学肿瘤诊所招募的。确定了皮尔逊积矩相关系数、组内相关系数(ICC)、测量标准误差(SEM)及其相关的95%置信区间、最小可检测差异(SDD)和一致性界限作为重复性的结果指标。肘部力量的皮尔逊积矩相关系数和ICC结果为0.90,膝部伸展力量为0.96。SDD方面的结果是,肘部力量为29.4牛顿(N),膝部力量为54.8 N。肘部力量的一致性界限为 -21.7 N和38.5 N(平均8.4 N)。膝部力量的一致性界限为 -49.8 N和59.8 N(平均5 N)。皮尔逊积矩相关系数和ICC表明重复性良好。然而,更具信息量的重复性指标,即SEM和SDD,显示测试人员之间的测量误差相对较大。因此,目前不支持在癌症患者中使用MFB50K测量肌肉力量。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验